Leave Your Message
China Factory Suppliers: High-Performance Baudouin Diesel Generator Sets from 20kVA to 2750kVA
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm) Download
KVA KW KVA KW
TB20 20 16 18 15 4M06G20/5 2.3 4.7 1425*680*1140 2396*1056*1723 Details
TB25 25 20 23 18 4M06G25/5 2.3 6.1 1460*680*1140 2396*1056*1723 Details
TB35 35 28 32 26 4M06G35/5 2.3 7.6 1580*735*1150 2396*1056*1723 Details
TB44 44 35 40 32 4M06G44/5 2.3 9.5 1600*735*1150 2396*1056*1723 Details
TB50 50 40 45 36 4M06G50/5 2.3 10.7 1565*680*1150 2396*1056*1723 Details
TB55 55 44 50 40 4M06G55/5 2.3 11.9 1585*680*1150 2396*1056*1723 Details
TB72 72 57 65 52 4M10G70/5 4.087 15 1890*785*1240 3146*1056*1850 Details
TB88 88 70 80 64 4M10G88/5 4.087 18.8 1940*785*1240 3146*1056*1850 Details
TB110 110 88 100 80 4M10G110/5 4.087 21.3 1965*791*1345 3146*1056*1850 Details
TB150 150 120 135 108 6M11G150/5 6.75 30.2 2400*860*1460 3436*1106*1968 Details
TB165 165 132 150 120 6M11G165/5 6.75 32.6 2400*860*1460 3436*1106*1968 Details
TB220 220 176 200 160 6M16G220/5 9.726 43.1 2715*1085*1615 3686*1256*2068 Details
TB250 250 200 230 184 6M16G250/5 9.726 50.9 2770*1085*1615 3686*1256*2068 Details
TB275 275 220 250 200 6M16G275/5 9.726 56.9 2770*1085*1615 3686*1256*2068 Details
TB350 350 280 320 256 6M16G350/5 9.726 70.5 2895*1135*1660 4366*1406*2260 Details
TB400 400 320 375 300 6M21G400/5 12.54 82.1 3010*1150*1715 4786*1356*2537 Details
TB440 440 352 400 320 6M21G440/5 12.54 85.5 3010*1150*1715 4786*1356*2537 Details
TB500 500 400 450 360 6M21G500/5 12.54 96.58 3055*1155*1725 5306*1566*2585 Details
TB550 550 440 500 400 6M21G550/5 12.54 109.5 3140*1285*1840 5306*1566*2585 Details
TB660 660 528 600 480 6M33G660/5 19.6 126.5 3555*1360*2085 6058*2438*2591 Details
TB715 715 572 650 520 6M33G715/5 19.6 136.3 3630*1360*2085 6058*2438*2591 Details
TB750 738 590 670 536 6M33G750/5 19.6 151.1 3630*1360*2085 6058*2438*2591 Details
TB825 825 660 750 600 6M33G825/5 19.6 161.5 3700*1360*2085 6058*2438*2591 Details
TB900 900 720 815 652 12M26G900/5 31.8 173.7 4210*1800*2500 Please contact us if necessary Details
TB1000 1000 800 900 720 12M26G1000/5 31.8 195.5 4210*1800*2500 Details
TB1120 1120 898 1020 816 12M26G1100/5 31.8 207.1 4330*1800*2500 Details
TB1250 1230 984 1150 920 12M33G1250/5 39.2 236.2 4625*1925*2745 Details
TB1400 1400 1120 1250 1000 12M33G1400/5 39.2 258.6 4720*1925*2745 Details
TB1500 1500 1200 1375 1100 12M33G1500/5 39.2 296.9 4720*1925*2745 Details
TB1650 1650 1320 1500 1200 12M33G1650/5 39.2 324 4755*2295*2740 Details
TB1900 1873 1498 1750 1400 16M33G1900/5 52.3 364.3 5170*2290*2835 Details
TB2000 2000 1600 1875 1500 16M33G2000/5 52.3 401 5170*2290*2835 Details
TB2250 2250 1800 2000 1600 16M33G2250/5 52.3 485.3 5375*2810*3220 Details
TB2500 2500 2000 2250 1800 20M33G2500/5 65.4 495 6685*2295*3005 Details
TB2750 2750 2200 2500 2000 12M55G2750/5 65.65 513.9 6530*2300*3140 Details
ⓘ The above unit size and silent size are for reference only.
Frequently Asked Questions
Q What is the difference between ESP and PRP ratings for these diesel gensets?
ESP (Emergency Standby Power) is the maximum power output available for variable loads in the event of a utility failure, typically used for up to 200 hours per year. PRP (Prime Rated Power) is the power available for an unlimited number of hours per year, supplying a variable load. PRP output is generally lower than ESP to ensure long-term engine reliability.
Q What power range do the TB Series diesel generators cover?
The TB Series covers a wide power range from 20 KVA (TB20) up to 2750 KVA (TB2750), making it suitable for small commercial applications all the way through to large industrial and utility-scale power requirements.
Q Are canopy (silent) type enclosures available for all models?
Canopy type enclosures are available for models TB20 through TB825. For larger models from TB900 to TB2750, canopy specifications are available upon request — please contact us directly for customized solutions for these high-capacity units.
Q Where can I download the detailed specification sheet for a specific model?
Each model in the table above has a dedicated "Details" download button that links directly to its PDF specification sheet. Simply click the green "Details" button in the Download column next to the model you are interested in to access the full technical datasheet.
Q What engine brands are used in the TB Series generator sets?
The TB Series uses engines from the 4M06, 4M10, 6M11, 6M16, 6M21, 6M33, 12M26, 12M33, 16M33, 20M33, and 12M55 engine families. These are purpose-built industrial diesel engines designed for reliable genset applications with high fuel efficiency and long service intervals.
Q Are the dimensions listed in the table the final reference dimensions?
The unit dimensions (L*W*H in mm) listed in the table for both open type and canopy type configurations are provided for reference purposes only. Actual dimensions may vary slightly depending on optional accessories, specific configurations, or custom requirements. Please consult our technical team for precise dimensions before installation planning.