China R-M Series Gas Power Generator Set - Reliable Suppliers & Factory Engineered for Performance and Efficiency
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

📱 Scroll horizontally to view full table

Genset Model Standby Power Prime Power Engine Model Displacement (L) Fuel Consumption (L/h) Open Type L*W*H (mm) Canopy Type L*W*H (mm)
KVA KW KVA KW
TC30 30 24 27 22 4B3.9-G2 3.9 6.7 1856*835*1351 2396*1056*1723
TC44 44 35 40 32 4BT3.9-G2 3.9 9.3 1856*835*1351 2396*1056*1723
TC62 62 50 56 45 *4BTA3.9-G2 3.9 12.9 1856*835*1351 2396*1056*1723
TC70 70 56 65 52 △4BTA3.9-G2 3.9 14.9 1856*835*1351 2396*1056*1723
TC90 90 72 80 64 4BTA3.9-G11 3.9 17.6 1890*860*1400 3146*1056*1850
TC100 103 82 94 75 *6BT5.9-G2 5.9 22.3 2239*900*1412 3146*1056*1850
TC115 115 92 105 84 △6BT5.9-G2 5.9 24.2 2239*900*1412 3146*1056*1850
TC125 125 100 115 92 6BTA5.9-G2 5.9 27 2239*900*1412 3146*1056*1850
TC145 145 116 135 108 6BTAA5.9-G2 5.9 30 2372*988*1533 3436*1106*1968
TC165 165 132 150 120 6BTAA5.9-G12 5.9 34 * 2400*995*1533 3436*1106*1968
TC200 200 160 180 145 6CTA8.3-G2 8.3 42 2372*988*1533 3436*1106*1968
TC220 215 172 200 160 6CTAA8.3-G2 8.3 45 2584*1008*1667 3686*1256*2068
TC265 264 211 250 200 6LTAA8.9-G2 8.9 53 2584*1008*1667 3686*1256*2068
TC275 275 220 250 200 6LTAA8.9-G3 8.9 54 2584*1008*1667 3686*1256*2068
TC300 300 240 270 216 6LTAA9.5-G3 9.5 58 * 2950*1200*1760 4366*1406*2260
TC315 313 250 275 220 NTA855-G1A 14 61.3 3134*1147*1897 4366*1406*2260
TC350 340 272 310 248 NTA855-G1B 14 71.4 * 3134*1147*1897 4366*1406*2260
TC375 375 300 344 275 NTA855-G2A 14 71.9 3134*1147*1897 4366*1406*2260
TC385 388 310 350 280 NTA855-G4 14 75.3 * 3362*1150*1936 4786*1356*2537
TC410 413 330 375 300 NTAA855-G7 14 85.4 * 3362*1150*1936 4786*1356*2537
TC450 450 360 / / NTAA855-G7A 14 98 3362*1150*1936 4786*1356*2537
TC500 500 400 450 360 KTA19-G3 19 98.8 3452*1360*2131 5306*1566*2585
TC550 563 450 500 400 KTA19-G3A 19 109.6 3452*1360*2131 5306*1566*2585
TC550 563 450 500 400 KTA19-G4 19 109.6 * 3452*1360*2131 5306*1566*2585
TC625 631 505 525 420 KTAA19-G5 19 115.7 3630*1460*2050 6058*2438*2591
TC690 688 550 / / KTAA19-G6A 19 159 3647*1460*2050 6058*2438*2591
TC800 800 640 725 580 KT38-GA 38 174 * 4268*1770*2250 6058*2438*2591
TC825 825 660 750 600 KTA38-G2 38 168.7 4268*1770*2250 6058*2438*2591
TC880 888 710 800 640 KTA38-G2B 38 171.1 4320*2000*2263 6058*2438*2591
TC1000 1000 800 910 728 KTA38-G2A 38 198.8 4320*2000*2263 6058*2438*2591
TC1100 1100 880 1000 800 KTA38-G5 38 214.5 4320*2000*2263 6058*2438*2591
TC1250 1230 984 / / KTA38-G9 38 254 4350*2069*2263 12192*2438*2896
TC1375 1345 1076 1250 1000 KTA50-G3 50 267.5 4980*2060*2399 12192*2438*2896
TC1650 1650 1320 1375 1100 KTA50-G8 50.3 289 5680*2150*2562 12192*2438*2896
TC1650 1650 1320 1475 1180 KTA50-GS8 50 316.9 5680*2150*2562 12192*2438*2896
TC1875 1873 1498 1675 1340 KTA50-G15 50.3 350.6 5555*2050*2420 12192*2438*2896
TC2000 2000 1600 1875 1500 KTA50-G16 50.3 404.8 5990*2160*2543
ℹ️  *4BTA3.9-G2: QC 50/60E  |  △4BTA3.9-G2: QC 58/67E  |  *6BT5.9-G2: QC 86/100E  |  △6BT5.9-G2: QC 96/115E

Frequently Asked Questions

Q What is the difference between Standby Power and Prime Power in these generator sets?
Standby Power (ESP) refers to the maximum output available for use in the event of a utility failure, typically rated for up to 200 hours per year with an average load factor of 70%. Prime Power (PRP) is the maximum power available for an unlimited number of hours per year, with variable load. For continuous or primary power applications, the Prime Power rating should always be referenced.
Q What range of power output do these Cummins generator sets cover?
The TC series Cummins generator sets cover a wide power range from 30 KVA (TC30) up to 2000 KVA (TC2000), making them suitable for applications ranging from small commercial facilities to large industrial plants and data centers.
Q What is the difference between the Open Type and Canopy Type configurations?
The Open Type configuration exposes the engine and alternator without an enclosure, making it suitable for installation in a dedicated generator room or indoor environment. The Canopy Type features a weatherproof acoustic enclosure, ideal for outdoor installation, offering noise reduction and protection against the elements. Canopy units are generally larger in overall dimensions.
Q Which engine displacement options are available across the TC generator series?
The TC series uses Cummins engines ranging from 3.9L displacement (4B and 4BT series engines) for smaller models, through 5.9L (6BT/6BTA series), 8.3L and 8.9L and 9.5L (6CTA/6LTAA series), 14L (NTA855/NTAA855 series), 19L (KTA19/KTAA19 series), 38L (KT38/KTA38 series), up to 50L (KTA50 series) for the largest models.
Q How is fuel consumption determined, and what factors can affect it?
The fuel consumption figures listed (in L/h) are based on operation at 100% of the rated load under standard conditions. Actual fuel consumption may vary depending on the load percentage, ambient temperature and altitude, fuel quality, engine maintenance condition, and operating hours. Running at partial load will generally result in lower fuel consumption per hour.
Q Can these generator sets be customized for specific installation requirements?
Yes. The TC series generator sets can be configured to meet specific project requirements, including custom voltage and frequency output (50Hz or 60Hz), automatic transfer switch (ATS) integration, paralleling capability for multiple units, remote monitoring systems, and various fuel tank options. Please consult with our technical team for tailored solutions.