Leave Your Message
China Suppliers: TC Series Diesel Generator Sets with Cummins Engines - 30kVA to 2000kVA Factory Performance
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

Genset Model Standby Power Prime Power Engine Model Displacement (L) Fuel Consumption (L/h) Open Type L×W×H (mm) Canopy Type L×W×H (mm) Download
KVA KW KVA KW
TC30 30 24 27 22 4B3.9-G2 3.9 6.7 1856×835×1351 2396×1056×1723 Details
TC44 44 35 40 32 4BT3.9-G2 3.9 9.3 1856×835×1351 2396×1056×1723 Details
TC62 62 50 56 45 *4BTA3.9-G2 3.9 12.9 1856×835×1351 2396×1056×1723 Details
TC70 70 56 65 52 △4BTA3.9-G2 3.9 14.9 1856×835×1351 2396×1056×1723 Details
TC90 90 72 80 64 4BTA3.9-G11 3.9 17.6 1890×860×1400 3146×1056×1850 Details
TC100 103 82 94 75 *6BT5.9-G2 5.9 22.3 2239×900×1412 3146×1056×1850 Details
TC115 115 92 105 84 △6BT5.9-G2 5.9 24.2 2239×900×1412 3146×1056×1850 Details
TC125 125 100 115 92 6BTA5.9-G2 5.9 27 2239×900×1412 3146×1056×1850 Details
TC145 145 116 135 108 6BTAA5.9-G2 5.9 30 2372×988×1533 3436×1106×1968 Details
TC165 165 132 150 120 6BTAA5.9-G12 5.9 34 * 2400×995×1533 3436×1106×1968 Details
TC200 200 160 180 145 6CTA8.3-G2 8.3 42 2372×988×1533 3436×1106×1968 Details
TC220 215 172 200 160 6CTAA8.3-G2 8.3 45 2584×1008×1667 3686×1256×2068 Details
TC265 264 211 250 200 6LTAA8.9-G2 8.9 53 2584×1008×1667 3686×1256×2068 Details
TC275 275 220 250 200 6LTAA8.9-G3 8.9 54 2584×1008×1667 3686×1256×2068 Details
TC300 300 240 270 216 6LTAA9.5-G3 9.5 58 * 2950×1200×1760 4366×1406×2260 Details
TC315 313 250 275 220 NTA855-G1A 14 61.3 3134×1147×1897 4366×1406×2260 Details
TC350 340 272 310 248 NTA855-G1B 14 71.4 * 3134×1147×1897 4366×1406×2260 Details
TC375 375 300 344 275 NTA855-G2A 14 71.9 3134×1147×1897 4366×1406×2260 Details
TC385 388 310 350 280 NTA855-G4 14 75.3 * 3362×1150×1936 4786×1356×2537 Details
TC410 413 330 375 300 NTAA855-G7 14 85.4 * 3362×1150×1936 4786×1356×2537 Details
TC450 450 360 / / NTAA855-G7A 14 98 3362×1150×1936 4786×1356×2537 Details
TC500 500 400 450 360 KTA19-G3 19 98.8 3452×1360×2131 5306×1566×2585 Details
TC550 563 450 500 400 KTA19-G3A 19 109.6 3452×1360×2131 5306×1566×2585 Details
TC550 563 450 500 400 KTA19-G4 19 109.6 * 3452×1360×2131 5306×1566×2585 Details
TC625 631 505 525 420 KTAA19-G5 19 115.7 3630×1460×2050 6058×2438×2591 Details
TC690 688 550 / / KTAA19-G6A 19 159 3647×1460×2050 6058×2438×2591 Details
TC800 800 640 725 580 KT38-GA 38 174 * 4268×1770×2250 6058×2438×2591 Details
TC825 825 660 750 600 KTA38-G2 38 168.7 4268×1770×2250 6058×2438×2591 Details
TC880 888 710 800 640 KTA38-G2B 38 171.1 4320×2000×2263 6058×2438×2591 Details
TC1000 1000 800 910 728 KTA38-G2A 38 198.8 4320×2000×2263 6058×2438×2591 Details
TC1100 1100 880 1000 800 KTA38-G5 38 214.5 4320×2000×2263 6058×2438×2591 Details
TC1250 1230 984 / / KTA38-G9 38 254 4350×2069×2263 12192×2438×2896 Details
TC1375 1345 1076 1250 1000 KTA50-G3 50 267.5 4980×2060×2399 12192×2438×2896 Details
TC1650 1650 1320 1375 1100 KTA50-G8 50.3 289 5680×2150×2562 12192×2438×2896 Details
TC1650 1650 1320 1475 1180 KTA50-GS8 50 316.9 5680×2150×2562 12192×2438×2896 Details
TC1875 1873 1498 1675 1340 KTA50-G15 50.3 350.6 5555×2050×2420 12192×2438×2896 Details
TC2000 2000 1600 1875 1500 KTA50-G16 50.3 404.8 5990×2160×2543 Details
i Notes: *4BTA3.9-G2: QC 50/60E  |  △4BTA3.9-G2: QC 58/67E  |  *6BT5.9-G2: QC 86/100E  |  △6BT5.9-G2: QC 96/115E
Frequently Asked Questions
Q What is the difference between Standby Power and Prime Power in these Cummins gensets?
Standby Power refers to the maximum output available for emergency use when utility power fails — it is intended for use with varying loads and is not suitable for continuous operation. Prime Power is the maximum power available for an unlimited number of hours per year in a variable load application. For most continuous or prime applications, the Prime Power rating should be used when selecting the appropriate genset model.
Q Which genset models are available in both Open Type and Canopy (Soundproof) configurations?
All models listed in the table — from TC30 to TC2000 — are available in both Open Type and Canopy Type configurations. The Open Type genset is suitable for installation in engine rooms or protected environments, while the Canopy Type provides weatherproof and noise-reduced enclosure for outdoor or noise-sensitive applications. Dimensional specifications for both configurations are provided in the table above.
Q What engine brands and series are used across the TC genset range?
The TC series generators use Cummins engines exclusively across the entire range. The engine series includes the 4B/4BT/4BTA (3.9L), 6BT/6BTA/6BTAA (5.9L), 6CTA/6CTAA (8.3L), 6LTAA (8.9L/9.5L), NTA/NTAA855 (14L), KTA19/KTAA19 (19L), KT38/KTA38 (38L), and KTA50 (50–50.3L) series — covering power outputs from 30 KVA up to 2000 KVA.
Q How do I choose the right genset model for my power requirements?
To select the correct genset, first calculate your total connected load in KW or KVA. For standby backup applications (e.g., emergency power during outages), use the Standby Power rating. For continuous or prime power applications (e.g., off-grid power supply or primary power source), use the Prime Power rating. It is generally recommended to size the generator so that your average load does not exceed 70–80% of the rated capacity to ensure longevity and fuel efficiency.
Q Can I download detailed technical specifications for each genset model?
Yes. Each genset model in the table above has a dedicated PDF datasheet available for download via the "Details" button in the Download column. The datasheets contain comprehensive technical specifications including electrical performance, engine data, alternator details, dimensions, weight, and applicable standards. Simply click the corresponding "Details" button next to your desired model to access the PDF file.
Q What does the asterisk (*) or triangle (△) symbol mean next to certain engine model names?
The asterisk (*) and triangle (△) symbols indicate specific engine variants with different power output configurations. As noted at the bottom of the specification table: *4BTA3.9-G2 corresponds to QC 50/60E; △4BTA3.9-G2 corresponds to QC 58/67E; *6BT5.9-G2 corresponds to QC 86/100E; and △6BT5.9-G2 corresponds to QC 96/115E. These notations help differentiate engine tuning levels that result in varying KVA/KW outputs within the same engine platform.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us