Leave Your Message
China TC Series Diesel Generator Sets with Cummins Engines - Reliable Power Solutions from Trusted Suppliers and Factory
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

Genset Model Standby Power Prime Power Engine Model Disp. (L) Fuel (L/h) Open Type L*W*H (mm) Canopy Type L*W*H (mm) Specs
KVA KW KVA KW
TC30 30 24 27 22 4B3.9-G2 3.9 6.7 1856*835*1351 2396*1056*1723 Details
TC44 44 35 40 32 4BT3.9-G2 3.9 9.3 1856*835*1351 2396*1056*1723 Details
TC62 62 50 56 45 *4BTA3.9-G2 3.9 12.9 1856*835*1351 2396*1056*1723 Details
TC70 70 56 65 52 △4BTA3.9-G2 3.9 14.9 1856*835*1351 2396*1056*1723 Details
TC90 90 72 80 64 4BTA3.9-G11 3.9 17.6 1890*860*1400 3146*1056*1850 Details
TC100 103 82 94 75 *6BT5.9-G2 5.9 22.3 2239*900*1412 3146*1056*1850 Details
TC115 115 92 105 84 △6BT5.9-G2 5.9 24.2 2239*900*1412 3146*1056*1850 Details
TC125 125 100 115 92 6BTA5.9-G2 5.9 27 2239*900*1412 3146*1056*1850 Details
TC145 145 116 135 108 6BTAA5.9-G2 5.9 30 2372*988*1533 3436*1106*1968 Details
TC165 165 132 150 120 6BTAA5.9-G12 5.9 34 2400*995*1533 3436*1106*1968 Details
TC200 200 160 180 145 6CTA8.3-G2 8.3 42 2372*988*1533 3436*1106*1968 Details
TC220 215 172 200 160 6CTAA8.3-G2 8.3 45 2584*1008*1667 3686*1256*2068 Details
TC265 264 211 250 200 6LTAA8.9-G2 8.9 53 2584*1008*1667 3686*1256*2068 Details
TC275 275 220 250 200 6LTAA8.9-G3 8.9 54 2584*1008*1667 3686*1256*2068 Details
TC300 300 240 270 216 6LTAA9.5-G3 9.5 58 2950*1200*1760 4366*1406*2260 Details
TC315 313 250 275 220 NTA855-G1A 14 61.3 3134*1147*1897 4366*1406*2260 Details
TC350 340 272 310 248 NTA855-G1B 14 71.4 3134*1147*1897 4366*1406*2260 Details
TC375 375 300 344 275 NTA855-G2A 14 71.9 3134*1147*1897 4366*1406*2260 Details
TC385 388 310 350 280 NTA855-G4 14 75.3 3362*1150*1936 4786*1356*2537 Details
TC410 413 330 375 300 NTAA855-G7 14 85.4 3362*1150*1936 4786*1356*2537 Details
TC450 450 360 / / NTAA855-G7A 14 98 3362*1150*1936 4786*1356*2537 Details
TC500 500 400 450 360 KTA19-G3 19 98.8 3452*1360*2131 5306*1566*2585 Details
TC550 563 450 500 400 KTA19-G3A 19 109.6 3452*1360*2131 5306*1566*2585 Details
TC625 631 505 525 420 KTAA19-G5 19 115.7 3630*1460*2050 6058*2438*2591 Details
TC690 688 550 / / KTAA19-G6A 19 159 3647*1460*2050 6058*2438*2591 Details
TC800 800 640 725 580 KT38-GA 38 174 4268*1770*2250 6058*2438*2591 Details
TC825 825 660 750 600 KTA38-G2 38 168.7 4268*1770*2250 6058*2438*2591 Details
TC880 888 710 800 640 KTA38-G2B 38 171.1 4320*2000*2263 6058*2438*2591 Details
TC1000 1000 800 910 728 KTA38-G2A 38 198.8 4320*2000*2263 6058*2438*2591 Details
TC1100 1100 880 1000 800 KTA38-G5 38 214.5 4320*2000*2263 6058*2438*2591 Details
TC1250 1230 984 / / KTA38-G9 38 254 4350*2069*2263 12192*2438*2896 Details
TC1375 1345 1076 1250 1000 KTA50-G3 50 267.5 4980*2060*2399 12192*2438*2896 Details
TC1650 1650 1320 1375 1100 KTA50-G8 50.3 289 5680*2150*2562 12192*2438*2896 Details
TC1875 1873 1498 1675 1340 KTA50-G15 50.3 350.6 5555*2050*2420 12192*2438*2896 Details
*4BTA3.9-G2: QC 50/60E | △4BTA3.9-G2: QC 58/67E
*6BT5.9-G2: QC 86/100E | △6BT5.9-G2: QC 96/115E
💡 Frequently Asked Questions
What is the difference between Standby and Prime Power?
Standby Power is the maximum power available for a variable load during a utility power outage. Prime Power is the maximum power available for continuous use with variable load, typically used where utility power is unavailable.
Which engine models are featured in the TC series gensets?
The series utilizes a variety of high-performance engines, including the 4B3.9, 6BT5.9, 6CTA8.3, NTA855, KTA19, KTA38, and KTA50 series, catering to different power requirements.
How is the fuel consumption calculated for these generators?
Fuel consumption is measured in Liters per hour (L/h) based on the specific engine's performance at standard load conditions. For example, the TC30 consumes 6.7 L/h.
Are dimensions provided for both Open and Canopy types?
Yes, the technical table lists the Length*Width*Height (mm) for both Open Type and Canopy (Silent) Type for almost every model in the range.
Can I get a detailed technical datasheet for a specific model?
Absolutely. Each model row in the table includes a "Details" button that links directly to the official PDF specification sheet for that specific genset.
What is the maximum power capacity available in this series?
The series ranges from the TC30 (30 KVA standby) up to the TC2000 (2000 KVA standby), covering a wide spectrum of industrial and commercial power needs.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us

CONTACT US