Leave Your Message
High-Performance Diesel Generator Sets with Baudouin Engines - China Factory and Suppliers (20kVA-2750kVA)
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

← Scroll horizontally to view full table →

Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type
L*W*H (mm)
Canopy Type
L*W*H (mm)
Download
KVA KW KVA KW
TB20 20 16 18 15 4M06G20/5 2.3 4.7 1425*680*1140 2396*1056*1723 📄Details
TB25 25 20 23 18 4M06G25/5 2.3 6.1 1460*680*1140 2396*1056*1723 📄Details
TB35 35 28 32 26 4M06G35/5 2.3 7.6 1580*735*1150 2396*1056*1723 📄Details
TB44 44 35 40 32 4M06G44/5 2.3 9.5 1600*735*1150 2396*1056*1723 📄Details
TB50 50 40 45 36 4M06G50/5 2.3 10.7 1565*680*1150 2396*1056*1723 📄Details
TB55 55 44 50 40 4M06G55/5 2.3 11.9 1585*680*1150 2396*1056*1723 📄Details
TB72 72 57 65 52 4M10G70/5 4.087 15 1890*785*1240 3146*1056*1850 📄Details
TB88 88 70 80 64 4M10G88/5 4.087 18.8 1940*785*1240 3146*1056*1850 📄Details
TB110 110 88 100 80 4M10G110/5 4.087 21.3 1965*791*1345 3146*1056*1850 📄Details
TB150 150 120 135 108 6M11G150/5 6.75 30.2 2400*860*1460 3436*1106*1968 📄Details
TB165 165 132 150 120 6M11G165/5 6.75 32.6 2400*860*1460 3436*1106*1968 📄Details
TB220 220 176 200 160 6M16G220/5 9.726 43.1 2715*1085*1615 3686*1256*2068 📄Details
TB250 250 200 230 184 6M16G250/5 9.726 50.9 2770*1085*1615 3686*1256*2068 📄Details
TB275 275 220 250 200 6M16G275/5 9.726 56.9 2770*1085*1615 3686*1256*2068 📄Details
TB350 350 280 320 256 6M16G350/5 9.726 70.5 2895*1135*1660 4366*1406*2260 📄Details
TB400 400 320 375 300 6M21G400/5 12.54 82.1 3010*1150*1715 4786*1356*2537 📄Details
TB440 440 352 400 320 6M21G440/5 12.54 85.5 3010*1150*1715 4786*1356*2537 📄Details
TB500 500 400 450 360 6M21G500/5 12.54 96.58 3055*1155*1725 5306*1566*2585 📄Details
TB550 550 440 500 400 6M21G550/5 12.54 109.5 3140*1285*1840 5306*1566*2585 📄Details
TB660 660 528 600 480 6M33G660/5 19.6 126.5 3555*1360*2085 6058*2438*2591 📄Details
TB715 715 572 650 520 6M33G715/5 19.6 136.3 3630*1360*2085 6058*2438*2591 📄Details
TB750 738 590 670 536 6M33G750/5 19.6 151.1 3630*1360*2085 6058*2438*2591 📄Details
TB825 825 660 750 600 6M33G825/5 19.6 161.5 3700*1360*2085 6058*2438*2591 📄Details
TB900 900 720 815 652 12M26G900/5 31.8 173.7 4210*1800*2500 Please contact us if necessary 📄Details
TB1000 1000 800 900 720 12M26G1000/5 31.8 195.5 4210*1800*2500 📄Details
TB1120 1120 898 1020 816 12M26G1100/5 31.8 207.1 4330*1800*2500 📄Details
TB1250 1230 984 1150 920 12M33G1250/5 39.2 236.2 4625*1925*2745 📄Details
TB1400 1400 1120 1250 1000 12M33G1400/5 39.2 258.6 4720*1925*2745 📄Details
TB1500 1500 1200 1375 1100 12M33G1500/5 39.2 296.9 4720*1925*2745 📄Details
TB1650 1650 1320 1500 1200 12M33G1650/5 39.2 324 4755*2295*2740 📄Details
TB1900 1873 1498 1750 1400 16M33G1900/5 52.3 364.3 5170*2290*2835 📄Details
TB2000 2000 1600 1875 1500 16M33G2000/5 52.3 401 5170*2290*2835 📄Details
TB2250 2250 1800 2000 1600 16M33G2250/5 52.3 485.3 5375*2810*3220 📄Details
TB2500 2500 2000 2250 1800 20M33G2500/5 65.4 495 6685*2295*3005 📄Details
TB2750 2750 2200 2500 2000 12M55G2750/5 65.65 513.9 6530*2300*3140 📄Details
ⓘ The above unit size and silent size are for reference only.

Frequently Asked Questions

Q What is the difference between ESP and PRP ratings for these diesel gensets?
ESP (Emergency Standby Power) is the maximum power available for variable load in the event of a utility failure, typically used for up to 200 hours per year. PRP (Prime Rated Power) is the maximum power available continuously while supplying variable load for an unlimited number of hours per year. For most applications requiring continuous operation, PRP ratings should be used as the basis for selection.
Q What range of power output do these genset models cover?
The TB series gensets cover a wide power range from 20 KVA (TB20) up to 2,750 KVA (TB2750), making them suitable for a broad variety of applications — from small commercial facilities and construction sites to large industrial plants and data centers.
Q What is the difference between Open Type and Canopy Type gensets?
Open Type gensets have no enclosure, making them more compact and cost-effective, but they require installation in a dedicated engine room or shelter. Canopy Type (also called silent or soundproof) gensets are enclosed in a weatherproof, sound-attenuating housing, making them suitable for outdoor installation and noise-sensitive environments. The dimensions listed in the table reflect each configuration.
Q Are detailed technical specifications available for each model?
Yes. Each genset model in the table above has a downloadable PDF datasheet available by clicking the "Details" button in the Download column. The datasheets contain full technical specifications including electrical performance, engine parameters, dimensions, weight, and optional features.
Q Is canopy (silent) type available for the larger models above TB825?
For models TB900 and above, canopy type availability and dimensions are subject to specific project requirements. Please contact us directly to discuss your needs and we will provide the most suitable solution and detailed quotation.
Q How accurate are the dimensions and fuel consumption figures listed in the table?
The unit dimensions (L×W×H) and fuel consumption figures provided are for reference purposes only, as stated in the table footnote. Actual values may vary slightly depending on optional accessories, alternator configuration, control panel selection, and specific customer requirements. For precise engineering data, please refer to the individual model datasheet or contact our technical team.