Leave Your Message
High-Performance Diesel Generator Sets with Perkins Engines - China Suppliers & Factory, 10kVA to 2500kVA
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

Scroll horizontally to view all specifications. Click "Details" to download the full datasheet (PDF).
Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L×W×H (mm) Canopy Type L×W×H (mm) Download
KVA KW KVA KW
TP10 10 8 9 7 403A-11G1/403D-11G 1.1 2.6 1402×715×1155 1856×826×1415 Details
TP14 14 11 13 10 403D-15G 1.5 3.7 1402×715×1155 1856×826×1415 Details
TP15 15 11 13 10 403A-15G1 1.5 3.7 1402×715×1155 1856×826×1415 Details
TP22 22 18 20 16 404A-22G1/404D-22G 2.2 5.3 1402×715×1155 1856×826×1415 Details
TP33 33 26 30 24 1103A-33G 3.3 7.2 1765×785×1256 2396×1056×1723 Details
TP50 50 40 45 36 1103A-33TG1 3.3 7.2 1765×785×1256 2396×1056×1723 Details
TP66 66 53 60 48 1103A-33TG2 3.3 14.6 1765×785×1256 2396×1056×1723 Details
TP88 88 70 80 64 1104A-44TG2 4.4 18.7 1939×840×1309 3146×1056×1850 Details
TP110 110 88 100 80 1104C-44TAG2 4.4 22.6 1939×840×1309 3146×1056×1850 Details
TP150 150 120 135 108 1106A-70TG1 7 30.3 2481×1004×1534 3436×1106×1968 Details
TP165 165 132 150 120 1106A-70TAG2 7 33.4 2481×1004×1534 3436×1106×1968 Details
TP200 200 160 180 144 1106A-70TAG3 7 41.4 2481×1004×1534 3436×1106×1968 Details
TP220 220 176 200 160 1106A-70TAG4 7 45.8 2481×1004×1534 3436×1106×1968 Details
TP250 250 200 230 184 1206A-E70TTAG2 7.01 51 2830×1120×1660 3686×1256×2068 Details
TP275 275 220 250 200 1206A-E70TTAG3 7.01 56.9 2830×1120×1660 3686×1256×2068 Details
TP330 339 271 307 246 1706A-E93TAG1 9.29 69.6 2830×1125×1703 4366×1306×2250 Details
TP340 337 270 308 246 1506A-E88TAG5 8.8 64.9 2923×1120×1703 4366×1306×2250 Details
TP385 384 307 348 278 1706A-E93TAG2 9.29 78.4 2830×1125×1703 4786×1356×2537 Details
TP400 400 320 350 280 2206C-E13TAG2 12.5 75 3230×1187×1988 4786×1356×2537 Details
TP450 450 360 400 320 2206C-E13TAG3 12.5 85 3230×1187×1988 4786×1356×2537 Details
TP500 500 400 450 360 2506C-E15TAG1 15 99 3460×1182×1987 5306×1566×2585 Details
TP550 550 440 500 400 2506C-E15TAG2 15 106 3460×1182×1987 5306×1566×2585 Details
TP660 650 520 591 473 2806C-E18TAG1A 18.1 129 3465×1548×1980 6058×2438×2591 Details
TP700 700 560 650 520 2806A-E18TAG2 18.1 132 3505×1548×1980 6058×2438×2591 Details
TP825 820 656 746 597 4006-23TAG2A 22.9 161 4318×1720×2230 6058×2438×2591 Details
TP880 900 718 800 641 4006-23TAG3A 22.9 172 4318×1720×2230 6058×2438×2591 Details
TP1000 1000 800 900 720 4008TAG1A 30.6 195 4699×2070×2269 6058×2438×2591 Details
TP1100 1100 880 1000 800 4008TAG2 30.6 224 4699×2070×2269 6058×2438×2591 Details
TP1375 1345 1076 1250 1000 4012-46TWG2A 45.8 258 4811×2010×2448 12192×2438×2896 Details
TP1500 1500 1200 1350 1100 4012-46TWG3A 45.8 281 4811×2010×2448 12192×2438×2896 Details
TP1650 1650 1320 1500 1200 4012-46TAG2A 45.8 310 4985×2240×2569 12192×2438×2896 Details
TP1875 1873 1498 1710 1350 4012-46TAG3A 45.8 370 5070×2240×2569 12192×2438×2896 Details
TP2000 2000 1600 1850 1480 4016TAG1A 61.1 383 5990×2160×2543 12192×2438×2896 Details
TP2250 2250 1800 2000 1600 4016TAG2A 61.1 434 5990×2160×2543 12192×2438×2896 Details
TP2500 2500 2000 2250 1800 4016-61TRG3 61.1 470 6010×2250×2783.5 Details
Frequently Asked Questions
Q What is the difference between ESP and PRP ratings for these gensets?
ESP (Emergency Standby Power) refers to the maximum power output available for use in the event of a utility failure, typically for up to 200 hours per year with variable load. PRP (Prime Rated Power) is the power available for an unlimited number of hours per year with a variable load, generally at around 70–80% average load factor. Always select the rating that matches your actual application requirements.
Q What engine brand powers the TP Series gensets?
The TP Series generator sets are powered by Perkins engines, ranging from compact 1.1L displacement models (e.g., 403A-11G1 for the TP10) all the way up to 61.1L displacement engines (e.g., 4016TAG2A for the TP2250). Perkins engines are globally recognized for their reliability, fuel efficiency, and low emissions compliance.
Q What is the difference between Open Type and Canopy Type configurations?
Open Type gensets have no enclosure, making them suitable for indoor installation in a dedicated generator room where noise and weather protection are provided by the building structure. Canopy Type gensets feature a sound-attenuated, weatherproof enclosure, making them ideal for outdoor installation or locations where noise reduction and protection from the elements are required.
Q How do I choose the right genset model for my power needs?
To select the correct model, first calculate your total connected load in KW or KVA, then add a safety margin of at least 20–25% for future expansion and load spikes. Determine whether you need standby (ESP) or continuous/prime (PRP) power. Consult the detailed PDF datasheet for each model to review full electrical and mechanical specifications before making a final selection.
Q Where can I download the full technical datasheet for each genset model?
Each genset model in the table above has a dedicated "Details" button in the Download column. Clicking it will open or download the corresponding PDF datasheet, which includes full electrical specifications, mechanical dimensions, fuel consumption data, engine details, and installation guidelines.
Q What is the fuel consumption like for the larger TP Series models?
Fuel consumption naturally increases with output capacity. For example, the TP10 consumes approximately 2.6 L/h, while the TP2500 (2000 KW ESP) consumes around 470 L/h at full load. For accurate fuel planning and tank sizing, refer to the specific fuel consumption figures listed in the table and the detailed PDF datasheet for each model, which may include part-load consumption curves.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us

CONTACT US