Q
What is the difference between ESP and PRP ratings for these Mitsubishi gensets?
ESP (Emergency Standby Power) is the maximum power available for variable load in the event of a utility failure, typically for up to 200 hours per year with no overload capability. PRP (Prime Rated Power) is the power available for continuous operation with a variable load for an unlimited number of hours per year. For example, the TMC750 has an ESP of 738 KVA / 590 KW and a PRP of 660 KVA / 530 KW.
Q
Which engine models are used in the TMC Series large gensets?
The TMC Series uses Mitsubishi heavy-duty industrial engines across its range. Smaller models (TMC750, TMC825) use the S6R2 series engines, mid-range models (TMC1375–TMC1650) use S12R series engines, and the larger models (TMC1900–TMC2250) are powered by S16R series engines. The top-tier TMC2500 uses the S16R2-PTAW-C engine with a 79.9L displacement.
Q
Are canopy (soundproof enclosure) versions available for all TMC Series models?
Canopy type enclosures are available for models TMC750 through TMC1900. The TMC2000, TMC2250, and TMC2500 are currently listed without canopy type dimensions, and are typically supplied in open-type configuration. Please contact our sales team for custom enclosure options for these larger models.
Q
What is the fuel consumption range across the TMC Series gensets?
Fuel consumption varies significantly across the TMC Series depending on the engine size and output rating. The TMC750 consumes approximately 123 L/h, while the largest model, the TMC2500, consumes up to 464 L/h. Fuel efficiency should be evaluated in context of the output power delivered and the specific application requirements.
Q
Where can I download the detailed technical datasheet for each TMC Series model?
Each model in the TMC Series has a dedicated PDF datasheet available for download directly from the table above. Simply click the "Details" button in the Download column for the corresponding model (e.g., TMC750, TMC825, TMC1375, etc.) to access the full technical specifications in PDF format.
Q
What applications are the TMC Series large diesel generators suitable for?
The TMC Series generators, ranging from 738 KVA to 2500 KVA, are designed for large-scale industrial and commercial applications including data centers, hospitals, manufacturing plants, mining operations, oil and gas facilities, and large infrastructure projects that require reliable and high-capacity standby or prime power solutions.