High-Performance Perkins Engine Diesel Generator Sets 10kVA-2500kVA - Trusted China Suppliers & Factory
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

← Scroll to view full table →
Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type Canopy Type
KVA KW KVA KW L*W*H(mm) L*W*H(mm)
TP10 10 8 9 7 403A-11G1/403D-11G 1.1 2.6 1402*715*1155 1856*826*1415
TP14 14 11 13 10 403D-15G 1.5 3.7 1402*715*1155 1856*826*1415
TP15 15 11 13 10 403A-15G1 1.5 3.7 1402*715*1155 1856*826*1415
TP22 22 18 20 16 404A-22G1/404D-22G 2.2 5.3 1402*715*1155 1856*826*1415
TP33 33 26 30 24 1103A-33G 3.3 7.2 1765*785*1256 2396*1056*1723
TP50 50 40 45 36 1103A-33TG1 3.3 7.2 1765*785*1256 2396*1056*1723
TP66 66 53 60 48 1103A-33TG2 3.3 14.6 1765*785*1256 2396*1056*1723
TP88 88 70 80 64 1104A-44TG2 4.4 18.7 1939*840*1309 3146*1056*1850
TP110 110 88 100 80 1104C-44TAG2 4.4 22.6 1939*840*1309 3146*1056*1850
TP150 150 120 135 108 1106A-70TG1 7 30.3 2481*1004*1534 3436*1106*1968
TP165 165 132 150 120 1106A-70TAG2 7 33.4 2481*1004*1534 3436*1106*1968
TP200 200 160 180 144 1106A-70TAG3 7 41.4 2481*1004*1534 3436*1106*1968
TP220 220 176 200 160 1106A-70TAG4 7 45.8 2481*1004*1534 3436*1106*1968
TP250 250 200 230 184 1206A-E70TTAG2 7.01 51 2830*1120*1660 3686*1256*2068
TP275 275 220 250 200 1206A-E70TTAG3 7.01 56.9 2830*1120*1660 3686*1256*2068
TP330 339 271 307 246 1706A-E93TAG1 9.29 69.6 2830*1125*1703 4366*1306*2250
TP340 337 270 308 246 1506A-E88TAG5 8.8 64.9 2923*1120*1703 4366*1306*2250
TP385 384 307 348 278 1706A-E93TAG2 9.29 78.4 2830*1125*1703 4786*1356*2537
TP400 400 320 350 280 2206C-E13TAG2 12.5 75 3230*1187*1988 4786*1356*2537
TP450 450 360 400 320 2206C-E13TAG3 12.5 85 3230*1187*1988 4786*1356*2537
TP500 500 400 450 360 2506C-E15TAG1 15 99 3460*1182*1987 5306*1566*2585
TP550 550 440 500 400 2506C-E15TAG2 15 106 3460*1182*1987 5306*1566*2585
TP660 650 520 591 473 2806C-E18TAG1A 18.1 129 3465*1548*1980 6058*2438*2591
TP700 700 560 650 520 2806A-E18TAG2 18.1 132 3505*1548*1980 6058*2438*2591
TP825 820 656 746 597 4006-23TAG2A 22.9 161 4318*1720*2230 6058*2438*2591
TP880 900 718 800 641 4006-23TAG3A 22.9 172 4318*1720*2230 6058*2438*2591
TP1000 1000 800 900 720 4008TAG1A 30.6 195 4699*2070*2269 6058*2438*2591
TP1100 1100 880 1000 800 4008TAG2 30.6 224 4699*2070*2269 6058*2438*2591
TP1375 1345 1076 1250 1000 4012-46TWG2A 45.8 258 4811*2010*2448 12192*2438*2896
TP1500 1500 1200 1350 1100 4012-46TWG3A 45.8 281 4811*2010*2448 12192*2438*2896
TP1650 1650 1320 1500 1200 4012-46TAG2A 45.8 310 4985*2240*2569 12192*2438*2896
TP1875 1873 1498 1710 1350 4012-46TAG3A 45.8 370 5070*2240*2569 12192*2438*2896
TP2000 2000 1600 1850 1480 4016TAG1A 61.1 383 5990*2160*2543 12192*2438*2896
TP2250 2250 1800 2000 1600 4016TAG2A 61.1 434 5990*2160*2543 12192*2438*2896
TP2500 2500 2000 2250 1800 4016-61TRG3 61.1 470 6010*2250*2783.5
Download
Download
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
? Frequently Asked Questions
Q What is the difference between ESP and PRP ratings in these Perkins gensets?
ESP (Emergency Standby Power) refers to the maximum output available for varying loads in the event of a utility power failure, typically for up to 200 hours per year with an average load factor of 70%. PRP (Prime Rated Power) is the maximum power available for an unlimited number of hours per year with a 10% overload capability for 1 hour in every 12 hours of operation. All models in the table list both ratings so you can select the correct specification for your application.
Q What power range do these Perkins generator sets cover?
The product range spans from 10 KVA (TP10) up to 2,500 KVA (TP2500), covering a wide spectrum of applications including small commercial facilities, industrial plants, data centers, hospitals, and large infrastructure projects. With 35 models available, customers can find a precisely matched output for virtually any power requirement.
Q Are these generator sets available in both open type and canopy (soundproof) configurations?
Yes. All models are offered in both Open Type and Canopy Type configurations. The open type is suited for indoor installation or machine rooms where noise control is managed by the building structure. The canopy type features an acoustic enclosure for outdoor use or noise-sensitive environments. Dimensional data (L×W×H in mm) for both configurations is provided in the specification table above.
Q Where can I download the detailed technical datasheet for a specific model?
Each model in the table has a corresponding "Details" PDF download button in the rightmost column. Clicking the button will open the official technical datasheet for that specific genset model, including full electrical specifications, engine performance curves, dimensional drawings, and installation guidelines.
Q What Perkins engine series are used across the generator set lineup?
The lineup utilizes multiple Perkins engine series to match power requirements: the 400 Series (403, 404) for smaller outputs (10–22 KVA), the 1100 Series (1103, 1104, 1106) for mid-range outputs (33–220 KVA), the 1200 Series (1206) for 250–275 KVA, the 1500/1700 Series for 330–385 KVA, the 2200/2500/2800 Series for 400–700 KVA, and the high-power 4000 Series (4006, 4008, 4012, 4016) for outputs from 825 KVA up to 2,500 KVA.
Q How do I determine the correct fuel consumption estimate for my application?
The "Fuel Cons L/h" column in the table provides the fuel consumption rate in liters per hour at full load for each model. For example, the TP10 consumes 2.6 L/h while the TP2500 consumes 470 L/h at rated load. For partial-load operation (which is typical in real-world use), actual consumption will be proportionally lower. We recommend consulting the detailed PDF datasheet for each model, which includes fuel consumption curves at 25%, 50%, 75%, and 100% load for accurate operational cost estimation.