Leave Your Message
High-Performance TY Series Diesel Generator Sets by Yuchai | Reliable China Suppliers & Factory│22kVA-2750kVA
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

The above unit size and silent size are for reference only.
Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm)
KVA KW KVA KW
TY23 22 18 20 16 4D24G6 2.45 4.8 1856*835*1351.5 2396*1056*1723
TY28 28 22 25 20 4D24G7 2.45 6 1856*835*1351.5 2396*1056*1723
TY33 33 26 30 24 4D24TG2 2.45 7.3 1856*835*1351.5 2396*1056*1723
TY41 41 33 38 30 4D24TG0 2.45 9.3 1856*835*1351.5 2396*1056*1723
TY63 63 50 56 45 YC4D80-D34 4.21 14.8 1856*820*1271 2396*1056*1723
TY69 69 55 63 50 YC4D90-D34 4.21 17 1856*835*1351.5 2396*1056*1723
TY80 80 64 75 60 YC4D105-D34 4.21 19.6 2400*995*1428 3146*1056*1850
TY100 100 80 88 70 YC4D120-D31 4.21 21.9 2350*900*1412.5 3146*1056*1850
TY110 110 88 100 80 YC4A140-D30 4.84 25.6 2480*1125*1412.5 3146*1056*1850
TY110 110 88 100 80 YC4D140-D31 4.21 25.6 2150*880*1306 3146*1056*1850
TY125 125 100 113 90 YC4A155-D30 4.84 27.1 2239*900*1412.5 3146*1056*1850
TY125 125 100 113 90 YC4D155-D31 4.21 27.6 2239*900*1412.5 3146*1056*1850
TY125 125 100 113 90 YC4A165-D30 4.84 28.3 2239*900*1412.5 3146*1056*1850
TY150 150 120 138 110 YC4A190-D30 4.84 31.9 2200*950*1436 3436*1106*1968
TY165 163 130 150 120 YC6A205-D30 7.25 35.3 2400*1000*1680 3436*1106*1968
TY188 188 150 175 140 YC6A230-D30 7.25 39.8 2450*1000*1680 3436*1106*1968
TY200 200 160 180 144 YC6A245-D30 7.25 41.8 2450*1000*1680 3436*1106*1968
TY220 220 176 200 160 YC6A275-D30 7.25 47.1 2550*980*1209 3686*1256*2068
TY275 275 220 250 200 YC6MK350-D30 10.34 57.5 2600*1008*1667.5 3686*1256*2068
TY344 340 272 310 248 YC6MK420-D30 10.34 68.3 3150*1147*1897 4366*1406*2260
TY350 375 300 350 280 YC6MK450-D30 10.34 72.6 3174*1147*1897 4366*1406*2260
TY400 400 320 375 300 YC6K500-D30 12.16 83 3200*1360*2050 4786*1356*2537
TY400 400 320 375 300 YC6K500-D31 12.16 83 3200*1360*2050 4786*1356*2537
TY425 425 340 400 320 YC6K520-D30 12.16 87 3250*1360*1995 4786*1356*2537
TY500 500 400 450 360 YC6K600-D30 12.94 101 3350*1360*1818 5306*1566*2585
TY550 550 440 500 400 YC6T660-D31 16.35 113.8 3630*1460*2050 5306*1566*2585
TY625 625 500 563 450 YC6TD780-D31 19.6 137 3650*1460*2000 6058*2438*2591
TY690 688 550 625 500 YC6TD840-D31 19.6 144.5 3680*1670*2029 6058*2438*2591
TY750 738 590 670 536 YC6TD900-D31 19.6 154.3 3680*1460*2150 6058*2438*2591
TY825 825 660 750 600 YC6TD1000-D30 19.6 166.4 4248*1660*2195 6058*2438*2591
TY825 825 660 750 600 YC6C1020-D31 39.58 172.5 4248*1660*2195 6058*2438*2591
TY890 888 710 813 650 YC6C1070-D31 39.58 181.6 4268*1760*2340 6058*2438*2591
TY1000 1000 800 913 730 YC6C1220-D31 39.58 203.7 4380*1771*2463 6058*2438*2591
TY1100 1125 900 1000 800 YC12VTD1350-D30 39.2 225.3 4350*2000*2263 6058*2438*2591
TY1125 1125 900 1000 800 YC6C1320-D31 39.58 220.2 4380*1771*2463 6058*2438*2591
TY1250 1230 984 1125 900 YC6C1520-D31 39.58 253.3 4817*2145*2448 12192*2438*2896
TY1250 1230 984 1125 900 YC12VTD1500-D30 39.2 250.4 4810*2200*2630 12192*2438*2896
TY1375 1345 1076 1250 1000 YC6C1660-D30 39.58 276.8 4668*2033*2198 12192*2438*2896
TY1375 1345 1076 1250 1000 YC12VTD1680-D30 39.2 280.4 4985*2060*2399 12192*2438*2896
TY1375 1345 1076 1250 1000 YC12VC1680-D31 79.17 281.7 4985*2060*2399 12192*2438*2896
TY1500 1500 1200 1375 1100 YC12VTD1830-D30 39.2 305.7 4602*2130*2535 12192*2438*2896
TY1625 1625 1300 1500 1200 YC12VTD2000-D30 39.2 336.8 4516*2200*2611 12192*2438*2896
TY1650 1660 1328 1500 1200 YC12VC2070-D31 79.17 339.2 5620*2555*2836 /
TY1875 1873 1498 1688 1350 YC12VC2270-D31 79.17 370.6 5600*2050*2420 /
TY2000 2000 1600 1875 1500 YC12VC2510-D31 79.17 416.5 5800*2250*2600 /
TY2250 2250 1800 2080 1664 YC12VC2700-D31 79.17 441.9 5820*2250*2600 /
TY2500 2500 2000 2250 1800 YC16VC3000-D31 105.56 493.9 6000*2590*2770 /
TY2750 2750 2200 2500 2000 YC16VC3300-D31 105.56 543.2 6540*2575*3035 /
The above unit size and silent size are for reference only
Download
Download
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Download
Frequently Asked Questions
What is the difference between ESP and PRP ratings in these gensets?
ESP (Emergency Standby Power) is the maximum power output available for variable load applications for the duration of a power outage, typically up to 200 hours per year. PRP (Prime Rated Power) is the power available for unlimited hours of operation at variable load, making it suitable for continuous use as a primary power source. For most backup applications, ESP ratings apply, while PRP is used when the generator serves as the main power supply.
What is the difference between Open Type and Canopy Type gensets?
Open Type gensets are designed for indoor installation or use within a dedicated generator room, offering easier access for maintenance and lower initial cost. Canopy Type (also known as silent or soundproof type) gensets are enclosed in a weatherproof, noise-reducing housing, making them suitable for outdoor installation or environments where noise reduction is required. The canopy enclosure typically results in a larger overall footprint.
What engine brands are used in the TY series generator sets?
The TY series generator sets are powered by Yuchai engines, including various series such as the 4D, 4A, 6A, 6MK, 6K, 6T, 6TD, 6C, 12VTD, 12VC, and 16VC engine families. These engines cover a displacement range from 2.45 liters up to 105.56 liters, supporting generator outputs from 22 KVA all the way up to 2,750 KVA.
How do I choose the right genset model for my power requirements?
To select the correct genset, first calculate your total load in KW or KVA by adding up all connected equipment. Then add a safety margin of 20–25% to account for startup surges and future load growth. Determine whether you need ESP or PRP rating based on your usage pattern. Finally, consider installation space constraints by comparing the open type or canopy type dimensions listed in the specification table. You can download the detailed datasheet for each model using the "Details" links provided.
Are the dimensions listed in the table exact for installation planning?
The unit dimensions (L×W×H in mm) listed in the table for both Open Type and Canopy Type configurations are provided for reference purposes only. Actual dimensions may vary slightly due to manufacturing tolerances, optional accessories, or configuration changes. For precise installation planning, it is recommended to download the detailed product datasheet for your specific model or contact the manufacturer directly to obtain certified dimensional drawings.
Why are some genset models listed multiple times with different engine options?
Some genset models (such as TY110, TY125, TY400, TY825, and TY1375) appear multiple times in the table because they can be configured with different engine models offering the same or similar power output. This gives customers flexibility to choose based on engine displacement, fuel consumption preference, availability, or specific application requirements. Each engine variant has its own detailed datasheet available for download.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us

CONTACT US