Leave Your Message
High-Quality Diesel Generator Sets with Cummins Engines - Reliable China Suppliers & Factory for 30kVA-2000kVA Solutions
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

⟵ Scroll horizontally to view full table ⟶
Genset Model Standby Power Prime Power Engine Model Displacement (L) Fuel Consumption (L/h) Open Type Canopy Type
KVA KW KVA KW L*W*H(mm) L*W*H(mm)
TC30 30 24 27 22 4B3.9-G2 3.9 6.7 1856*835*1351 2396*1056*1723
TC44 44 35 40 32 4BT3.9-G2 3.9 9.3 1856*835*1351 2396*1056*1723
TC62 62 50 56 45 *4BTA3.9-G2 3.9 12.9 1856*835*1351 2396*1056*1723
TC70 70 56 65 52 △4BTA3.9-G2 3.9 14.9 1856*835*1351 2396*1056*1723
TC90 90 72 80 64 4BTA3.9-G11 3.9 17.6 1890*860*1400 3146*1056*1850
TC100 103 82 94 75 *6BT5.9-G2 5.9 22.3 2239*900*1412 3146*1056*1850
TC115 115 92 105 84 △6BT5.9-G2 5.9 24.2 2239*900*1412 3146*1056*1850
TC125 125 100 115 92 6BTA5.9-G2 5.9 27 2239*900*1412 3146*1056*1850
TC145 145 116 135 108 6BTAA5.9-G2 5.9 30 2372*988*1533 3436*1106*1968
TC165 165 132 150 120 6BTAA5.9-G12 5.9 34 * 2400*995*1533 3436*1106*1968
TC200 200 160 180 145 6CTA8.3-G2 8.3 42 2372*988*1533 3436*1106*1968
TC220 215 172 200 160 6CTAA8.3-G2 8.3 45 2584*1008*1667 3686*1256*2068
TC265 264 211 250 200 6LTAA8.9-G2 8.9 53 2584*1008*1667 3686*1256*2068
TC275 275 220 250 200 6LTAA8.9-G3 8.9 54 2584*1008*1667 3686*1256*2068
TC300 300 240 270 216 6LTAA9.5-G3 9.5 58 * 2950*1200*1760 4366*1406*2260
TC315 313 250 275 220 NTA855-G1A 14 61.3 3134*1147*1897 4366*1406*2260
TC350 340 272 310 248 NTA855-G1B 14 71.4 * 3134*1147*1897 4366*1406*2260
TC375 375 300 344 275 NTA855-G2A 14 71.9 3134*1147*1897 4366*1406*2260
TC385 388 310 350 280 NTA855-G4 14 75.3 * 3362*1150*1936 4786*1356*2537
TC410 413 330 375 300 NTAA855-G7 14 85.4 * 3362*1150*1936 4786*1356*2537
TC450 450 360 / / NTAA855-G7A 14 98 3362*1150*1936 4786*1356*2537
TC500 500 400 450 360 KTA19-G3 19 98.8 3452*1360*2131 5306*1566*2585
TC550 563 450 500 400 KTA19-G3A 19 109.6 3452*1360*2131 5306*1566*2585
TC550 563 450 500 400 KTA19-G4 19 109.6 * 3452*1360*2131 5306*1566*2585
TC625 631 505 525 420 KTAA19-G5 19 115.7 3630*1460*2050 6058*2438*2591
TC690 688 550 / / KTAA19-G6A 19 159 3647*1460*2050 6058*2438*2591
TC800 800 640 725 580 KT38-GA 38 174 * 4268*1770*2250 6058*2438*2591
TC825 825 660 750 600 KTA38-G2 38 168.7 4268*1770*2250 6058*2438*2591
TC880 888 710 800 640 KTA38-G2B 38 171.1 4320*2000*2263 6058*2438*2591
TC1000 1000 800 910 728 KTA38-G2A 38 198.8 4320*2000*2263 6058*2438*2591
TC1100 1100 880 1000 800 KTA38-G5 38 214.5 4320*2000*2263 6058*2438*2591
TC1250 1230 984 / / KTA38-G9 38 254 4350*2069*2263 12192*2438*2896
TC1375 1345 1076 1250 1000 KTA50-G3 50 267.5 4980*2060*2399 12192*2438*2896
TC1650 1650 1320 1375 1100 KTA50-G8 50.3 289 5680*2150*2562 12192*2438*2896
TC1650 1650 1320 1475 1180 KTA50-GS8 50 316.9 5680*2150*2562 12192*2438*2896
TC1875 1873 1498 1675 1340 KTA50-G15 50.3 350.6 5555*2050*2420 12192*2438*2896
TC2000 2000 1600 1875 1500 KTA50-G16 50.3 404.8 5990*2160*2543
*4BTA3.9-G2:QC 50/60E   △4BTA3.9-G2:QC 58/67E   *6BT5.9-G2:QC 86/100E   △6BT5.9-G2:QC 96/115E
Download
Download
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Download
Frequently Asked Questions
Q What is the difference between Standby Power and Prime Power in these genset models?
Standby Power (ESP) refers to the maximum power output available for use in the event of a utility failure. It is intended for limited hours of use per year with variable load. Prime Power (PRP) is the maximum power available for an unlimited number of hours per year with variable load. For example, the TC30 offers 30 KVA / 24 KW standby and 27 KVA / 22 KW prime power.
Q What engine brands are used in the TC series generator sets?
The TC series generator sets are powered by Cummins engines across the full range, including the 4B, 4BT, 4BTA, 6BT, 6BTA, 6BTAA, 6CTA, 6CTAA, 6LTAA, NTA855, KTA19, KTAA19, KT38, KTA38, and KTA50 engine families, covering displacements from 3.9L up to 50.3L to suit different power requirements.
Q What is the difference between the Open Type and Canopy Type configurations?
The Open Type generator set has no enclosure and is typically used in indoor or sheltered installations where noise and weather protection are not required. The Canopy Type (also called soundproof or enclosed type) features a protective housing that reduces noise levels and provides weather protection, making it suitable for outdoor use or noise-sensitive environments. The canopy version is generally larger in dimensions than the open type.
Q How do I select the right genset model for my power requirements?
To select the correct model, first calculate your total connected load in KW or KVA. Then determine whether you need standby or prime power operation. Add a safety margin of approximately 20–25% to your calculated load. For example, if your load is 80 KW prime power, the TC100 (94 KVA / 75 KW prime) or TC115 (105 KVA / 84 KW prime) would be appropriate choices. You can download the detailed specification sheet for each model using the "Details" button in the table.
Q What do the asterisk (*) and triangle (△) symbols mean in the engine model column?
As noted at the bottom of the table: *4BTA3.9-G2 corresponds to QC 50/60E rating; △4BTA3.9-G2 corresponds to QC 58/67E rating; *6BT5.9-G2 corresponds to QC 86/100E rating; and △6BT5.9-G2 corresponds to QC 96/115E rating. These symbols indicate specific performance certifications or output rating variants of the same engine platform.
Q Are detailed technical specification sheets available for each generator model?
Yes. Each generator model in the table has a corresponding downloadable PDF specification sheet. Simply click the "Details" button in the Download column next to the model you are interested in to access the full technical datasheet, which includes detailed electrical, mechanical, and dimensional specifications.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us

CONTACT US