Leave Your Message
MTU Engine Diesel Generator Sets TX Series – Power Solutions from China Suppliers and Factory (710kVA-3300kVA)
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

MTU Series Gensets — TX710 to TX1375 (2000 Engine Family)
Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm)
KVA KW KVA KW
TX710 715 572 650 520 12V2000G25 23.88 156 4000*1585*2265 5306*1706*3015
TX850 858 686 780 624 12V2000G65 23.88 185 4000*1585*2265 5306*1706*3015
TX1000 1001 801 910 728 16V2000G25 31.84 212.5 4350*1650*2253 6058*2438*2591
TX1100 1100 880 1000 800 16V2000G65 31.84 235.9 4430*1682*2285 6058*2438*2591
TX1250 1230 984 1135 908 18V2000G65 35.82 266.3 4750*2015*2340 12192*2438*2896
TX1375 1345 1076 1250 1000 18V2000G26F 40.2 275.9 4845*2015*2350 12192*2438*2896
Download
Download
Details
Details
Details
Details
Details
Details
MTU Series Gensets — TX1500 to TX3300 (4000 Engine Family)
Genset Model ESP PRP Engine Type
New Domestic Model
Engine Type
Imported MTU Model
Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm)
KVA KW KVA KW
TX1500 1500 1200 1365 1092 12V4000G23RF 12V4000G14RF 57.2 306.5 5750*2275*2600
TX1800 1760 1408 1600 1280 12V4000G23F 12V4000G14F 57.2 355.6 5750*2275*2600
TX2000 1980 1584 1800 1440 12V4000G63F 12V4000G24F 57.2 400.8 5870*2300*2702
TX2250 2250 1800 2080 1664 16V4000G23F 16V4000G14F 76.3 448 5870*2300*2705
TX2475 2400 1920 2250 1800 16V4000G63F 16V4000G24F 76.3 492.3 5870*2300*2705
TX2750 2680 2144 2500 2000 20V4000G23F 20V4000G14F 95.4 559.8 6535*2575*3035
TX3000 3070 2456 2790 2232 20V4000G63F 20V4000G24F 95.4 609.4 6535*2575*3035
TX3300 3300 2640 3000 2400 20V4000G63LF 20V4000G34F 95.4 659 6535*2575*3035
Frequently Asked Questions
Q What is the difference between ESP and PRP ratings for these MTU gensets?
ESP (Emergency Standby Power) is the maximum power available for variable load in the event of a utility failure, with no limitation on annual hours of use. PRP (Prime Rated Power) is the maximum power available continuously while supplying variable load for an unlimited number of hours per year. ESP output is typically higher than PRP for the same genset model.
Q What engine families power the TX-series gensets listed in these tables?
The TX710 to TX1375 models are powered by MTU 2000 series engines (12V2000, 16V2000, and 18V2000 variants), with displacements ranging from 23.88 L to 40.2 L. The TX1500 to TX3300 models use MTU 4000 series engines (12V4000, 16V4000, and 20V4000 variants), available in both new domestic models and imported MTU models, with displacements from 57.2 L to 95.4 L.
Q What is the difference between the Open Type and Canopy Type configurations?
The Open Type genset is a standard configuration without an enclosure, suitable for installation in a dedicated generator room or protected indoor environment. The Canopy Type includes a weather-resistant acoustic enclosure, making it suitable for outdoor installation. Canopy Type units are generally larger in overall dimensions due to the enclosure. Note that canopy dimensions are not listed for the TX1500–TX3300 series.
Q What is the difference between the New Domestic engine model and the Imported MTU engine model for the TX1500–TX3300 range?
The New Domestic model engines are manufactured locally under license and offer a cost-effective solution while maintaining reliable performance. The Imported MTU model engines are sourced directly from MTU (Germany), offering original OEM specifications with potentially different certifications and service support networks. Both engine types share the same genset frame and electrical output specifications for each model.
Q How do I download the detailed technical specification sheet for a specific genset model?
Each genset model has a corresponding "Details" download button in the Download column on the right side of the specification table. Click the button for your chosen model to open or download the PDF datasheet. For the TX1500–TX3300 series, separate datasheets are available for both the New Domestic engine variant and the Imported MTU engine variant.
Q Which genset model is suitable for applications requiring over 2,000 kW of prime power?
For applications requiring more than 2,000 kW at PRP rating, the TX2250 (1,664 kW PRP), TX2475 (1,800 kW PRP), TX2750 (2,000 kW PRP), TX3000 (2,232 kW PRP), and TX3300 (2,400 kW PRP) models are available. All are powered by MTU 4000 series engines. Please consult the detailed PDF datasheet for each model or contact our sales team for project-specific sizing recommendations.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us

CONTACT US