Leave Your Message
Reliable China Diesel Generator Sets with Perkins Engines - TP Series Suppliers and Factory Solutions 10kVA-2500kVA
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

Scroll horizontally to view full table
Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm)
KVA KW KVA KW
TP10 10 8 9 7 403A-11G1/403D-11G 1.1 2.6 1402*715*1155 1856*826*1415
TP14 14 11 13 10 403D-15G 1.5 3.7 1402*715*1155 1856*826*1415
TP15 15 11 13 10 403A-15G1 1.5 3.7 1402*715*1155 1856*826*1415
TP22 22 18 20 16 404A-22G1/404D-22G 2.2 5.3 1402*715*1155 1856*826*1415
TP33 33 26 30 24 1103A-33G 3.3 7.2 1765*785*1256 2396*1056*1723
TP50 50 40 45 36 1103A-33TG1 3.3 7.2 1765*785*1256 2396*1056*1723
TP66 66 53 60 48 1103A-33TG2 3.3 14.6 1765*785*1256 2396*1056*1723
TP88 88 70 80 64 1104A-44TG2 4.4 18.7 1939*840*1309 3146*1056*1850
TP110 110 88 100 80 1104C-44TAG2 4.4 22.6 1939*840*1309 3146*1056*1850
TP150 150 120 135 108 1106A-70TG1 7 30.3 2481*1004*1534 3436*1106*1968
TP165 165 132 150 120 1106A-70TAG2 7 33.4 2481*1004*1534 3436*1106*1968
TP200 200 160 180 144 1106A-70TAG3 7 41.4 2481*1004*1534 3436*1106*1968
TP220 220 176 200 160 1106A-70TAG4 7 45.8 2481*1004*1534 3436*1106*1968
TP250 250 200 230 184 1206A-E70TTAG2 7.01 51 2830*1120*1660 3686*1256*2068
TP275 275 220 250 200 1206A-E70TTAG3 7.01 56.9 2830*1120*1660 3686*1256*2068
TP330 339 271 307 246 1706A-E93TAG1 9.29 69.6 2830*1125*1703 4366*1306*2250
TP340 337 270 308 246 1506A-E88TAG5 8.8 64.9 2923*1120*1703 4366*1306*2250
TP385 384 307 348 278 1706A-E93TAG2 9.29 78.4 2830*1125*1703 4786*1356*2537
TP400 400 320 350 280 2206C-E13TAG2 12.5 75 3230*1187*1988 4786*1356*2537
TP450 450 360 400 320 2206C-E13TAG3 12.5 85 3230*1187*1988 4786*1356*2537
TP500 500 400 450 360 2506C-E15TAG1 15 99 3460*1182*1987 5306*1566*2585
TP550 550 440 500 400 2506C-E15TAG2 15 106 3460*1182*1987 5306*1566*2585
TP660 650 520 591 473 2806C-E18TAG1A 18.1 129 3465*1548*1980 6058*2438*2591
TP700 700 560 650 520 2806A-E18TAG2 18.1 132 3505*1548*1980 6058*2438*2591
TP825 820 656 746 597 4006-23TAG2A 22.9 161 4318*1720*2230 6058*2438*2591
TP880 900 718 800 641 4006-23TAG3A 22.9 172 4318*1720*2230 6058*2438*2591
TP1000 1000 800 900 720 4008TAG1A 30.6 195 4699*2070*2269 6058*2438*2591
TP1100 1100 880 1000 800 4008TAG2 30.6 224 4699*2070*2269 6058*2438*2591
TP1375 1345 1076 1250 1000 4012-46TWG2A 45.8 258 4811*2010*2448 12192*2438*2896
TP1500 1500 1200 1350 1100 4012-46TWG3A 45.8 281 4811*2010*2448 12192*2438*2896
TP1650 1650 1320 1500 1200 4012-46TAG2A 45.8 310 4985*2240*2569 12192*2438*2896
TP1875 1873 1498 1710 1350 4012-46TAG3A 45.8 370 5070*2240*2569 12192*2438*2896
TP2000 2000 1600 1850 1480 4016TAG1A 61.1 383 5990*2160*2543 12192*2438*2896
TP2250 2250 1800 2000 1600 4016TAG2A 61.1 434 5990*2160*2543 12192*2438*2896
TP2500 2500 2000 2250 1800 4016-61TRG3 61.1 470 6010*2250*2783.5
Download
Download
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Frequently Asked Questions
Q What is the difference between ESP and PRP ratings in the genset specification table?
ESP (Emergency Standby Power) is the maximum power a generator can deliver for up to 200 hours per year with variable load, typically used as backup during utility outages. PRP (Prime Rated Power) is the power available for unlimited hours per year with variable load, suitable for continuous or prime power applications. ESP ratings are generally higher than PRP ratings for the same generator model.
Q What power range do these Perkins-powered gensets cover?
The genset range listed in this table covers a wide power spectrum, from 10 KVA (TP10) up to 2,500 KVA (TP2500), making them suitable for small commercial applications all the way through to large industrial and utility-scale power requirements.
Q Are both open type and canopy type configurations available for all models?
The majority of models in this range are available in both open type and canopy (soundproofed enclosure) configurations. The dimensions for both variants are listed in the specification table. Please note that the TP2500 model currently lists dimensions only for the open type configuration. Contact us for canopy availability on specific models.
Q How do I download the detailed datasheet for a specific genset model?
Each genset model has a corresponding "Details" download button in the rightmost column of the table. Clicking the button will open or download the PDF datasheet for that specific model, which includes full technical specifications, electrical data, and dimensional drawings.
Q What engine brands power the gensets listed in this table?
All genset models listed in this table are powered by Perkins engines. The engine models range from the compact 403A/403D series (used in smaller units like TP10–TP15) up to the large 4016 series engines (used in the TP2000–TP2500 models), covering displacements from 1.1 litres to 61.1 litres.
Q How should I select the right genset model for my application?
Selecting the correct genset depends on several factors: the total load (KW/KVA) you need to support, whether the application requires prime or standby power (PRP vs. ESP), installation space constraints (refer to the L*W*H dimensions), and whether a canopy enclosure is needed for noise reduction or outdoor use. We recommend consulting with our technical team to ensure the best model match for your specific project requirements.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us

CONTACT US