TC1100T

Specifications

Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm) Download
KVA KW KVA KW
TX710 715 572 650 520 12V2000G25 23.88 156 4000*1585*2265 5306*1706*3015 Details
TX850 858 686 780 624 12V2000G65 23.88 185 4000*1585*2265 5306*1706*3015 Details
TX1000 1001 801 910 728 16V2000G25 31.84 212.5 4350*1650*2253 6058*2438*2591 Details
TX1100 1100 880 1000 800 16V2000G65 31.84 235.9 4430*1682*2285 6058*2438*2591 Details
TX1250 1230 984 1135 908 18V2000G65 35.82 266.3 4750*2015*2340 12192*2438*2896 Details
TX1375 1345 1076 1250 1000 18V2000G26F 40.2 275.9 4845*2015*2350 12192*2438*2896 Details

Genset Model ESP PRP Engine Type
New Domestic Model
Engine Type
Imported MTU Model
Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm) Download (New) Download (MTU)
KVA KW KVA KW
TX1500 1500 1200 1365 1092 12V4000G23RF 12V4000G14RF 57.2 306.5 5750*2275*2600 Details Details
TX1800 1760 1408 1600 1280 12V4000G23F 12V4000G14F 57.2 355.6 5750*2275*2600 Details Details
TX2000 1980 1584 1800 1440 12V4000G63F 12V4000G24F 57.2 400.8 5870*2300*2702 Details Details
TX2250 2250 1800 2080 1664 16V4000G23F 16V4000G14F 76.3 448 5870*2300*2705 Details Details
TX2475 2400 1920 2250 1800 16V4000G63F 16V4000G24F 76.3 492.3 5870*2300*2705 Details Details
TX2750 2680 2144 2500 2000 20V4000G23F 20V4000G14F 95.4 559.8 6535*2575*3035 Details Details
TX3000 3070 2456 2790 2232 20V4000G63F 20V4000G24F 95.4 609.4 6535*2575*3035 Details Details
TX3300 3300 2640 3000 2400 20V4000G63LF 20V4000G34F 95.4 659 6535*2575*3035 Details Details

Frequently Asked Questions

Q
What is the difference between ESP and PRP ratings for these gensets?
ESP (Emergency Standby Power) refers to the maximum power output available for variable load applications in the event of a utility failure, typically with no more than 200 hours per year of operation. PRP (Prime Rated Power) is the maximum power available for continuous variable load operation for an unlimited number of hours per year. PRP is generally lower than ESP to ensure long-term engine reliability.
Q
What is the difference between the New Domestic engine model and the Imported MTU engine model in the TX1500–TX3300 series?
The New Domestic model refers to locally manufactured MTU-licensed engines (e.g., 12V4000G23RF), which offer cost-effective solutions while maintaining high performance standards. The Imported MTU model (e.g., 12V4000G14RF) refers to engines directly imported from MTU Germany, which may offer certain advantages in certification, warranty, or specific project requirements. Both share the same displacement and power output specifications.
Q
Are canopy (soundproof enclosure) versions available for all genset models in this range?
Canopy type dimensions are listed for the TX710–TX1375 series (MTU 2000 series). For the TX1500–TX3300 series (MTU 4000 series), canopy type dimensions are not listed in the current specification table. Please contact us directly for availability and custom canopy enclosure options for higher-power models.
Q
How do I select the right genset model for my power requirement?
To select the correct genset, first determine your total load in kW or kVA. If the generator is for standby (backup) use, select a model where the ESP kW rating meets or exceeds your load. If the generator will run continuously as a prime power source, select a model where the PRP kW rating meets your load. Always account for startup surge loads from motors or other inductive equipment, which may require additional capacity.
Q
Where can I download the detailed technical specification sheet for each genset model?
Each genset model has a dedicated PDF specification sheet available for download directly from the table above. Simply click the "Details" button in the Download column corresponding to your desired model. For the MTU 4000 series (TX1500–TX3300), separate PDF files are available for both the New Domestic engine version and the Imported MTU engine version.
Q
What fuel consumption should I expect from these high-power MTU gensets?
Fuel consumption varies by model and load level. At full ESP load, the TX710 consumes approximately 156 L/h, while the TX3300 consumes approximately 659 L/h. The figures listed in the specification table represent consumption at rated ESP output. Actual consumption at partial loads will be proportionally lower. For precise fuel planning, refer to the detailed PDF datasheet for each model, which includes consumption curves at various load percentages.