Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm)
KVA KW KVA KW
TP10 10 8 9 7 403A-11G1/403D-11G 1.1 2.6 1402*715*1155 1856*826*1415
TP14 14 11 13 10 403D-15G 1.5 3.7 1402*715*1155 1856*826*1415
TP15 15 11 13 10 403A-15G1 1.5 3.7 1402*715*1155 1856*826*1415
TP22 22 18 20 16 404A-22G1/404D-22G 2.2 5.3 1402*715*1155 1856*826*1415
TP33 33 26 30 24 1103A-33G 3.3 7.2 1765*785*1256 2396*1056*1723
TP50 50 40 45 36 1103A-33TG1 3.3 7.2 1765*785*1256 2396*1056*1723
TP66 66 53 60 48 1103A-33TG2 3.3 14.6 1765*785*1256 2396*1056*1723
TP88 88 70 80 64 1104A-44TG2 4.4 18.7 1939*840*1309 3146*1056*1850
TP110 110 88 100 80 1104C-44TAG2 4.4 22.6 1939*840*1309 3146*1056*1850
TP150 150 120 135 108 1106A-70TG1 7 30.3 2481*1004*1534 3436*1106*1968
TP165 165 132 150 120 1106A-70TAG2 7 33.4 2481*1004*1534 3436*1106*1968
TP200 200 160 180 144 1106A-70TAG3 7 41.4 2481*1004*1534 3436*1106*1968
TP220 220 176 200 160 1106A-70TAG4 7 45.8 2481*1004*1534 3436*1106*1968
TP250 250 200 230 184 1206A-E70TTAG2 7.01 51 2830*1120*1660 3686*1256*2068
TP275 275 220 250 200 1206A-E70TTAG3 7.01 56.9 2830*1120*1660 3686*1256*2068
TP330 339 271 307 246 1706A-E93TAG1 9.29 69.6 2830*1125*1703 4366*1306*2250
TP340 337 270 308 246 1506A-E88TAG5 8.8 64.9 2923*1120*1703 4366*1306*2250
TP385 384 307 348 278 1706A-E93TAG2 9.29 78.4 2830*1125*1703 4786*1356*2537
TP400 400 320 350 280 2206C-E13TAG2 12.5 75 3230*1187*1988 4786*1356*2537
TP450 450 360 400 320 2206C-E13TAG3 12.5 85 3230*1187*1988 4786*1356*2537
TP500 500 400 450 360 2506C-E15TAG1 15 99 3460*1182*1987 5306*1566*2585
TP550 550 440 500 400 2506C-E15TAG2 15 106 3460*1182*1987 5306*1566*2585
TP660 650 520 591 473 2806C-E18TAG1A 18.1 129 3465*1548*1980 6058*2438*2591
TP700 700 560 650 520 2806A-E18TAG2 18.1 132 3505*1548*1980 6058*2438*2591
TP825 820 656 746 597 4006-23TAG2A 22.9 161 4318*1720*2230 6058*2438*2591
TP880 900 718 800 641 4006-23TAG3A 22.9 172 4318*1720*2230 6058*2438*2591
TP1000 1000 800 900 720 4008TAG1A 30.6 195 4699*2070*2269 6058*2438*2591
TP1100 1100 880 1000 800 4008TAG2 30.6 224 4699*2070*2269 6058*2438*2591
TP1375 1345 1076 1250 1000 4012-46TWG2A 45.8 258 4811*2010*2448 12192*2438*2896
TP1500 1500 1200 1350 1100 4012-46TWG3A 45.8 281 4811*2010*2448 12192*2438*2896
TP1650 1650 1320 1500 1200 4012-46TAG2A 45.8 310 4985*2240*2569 12192*2438*2896
TP1875 1873 1498 1710 1350 4012-46TAG3A 45.8 370 5070*2240*2569 12192*2438*2896
TP2000 2000 1600 1850 1480 4016TAG1A 61.1 383 5990*2160*2543 12192*2438*2896
TP2250 2250 1800 2000 1600 4016TAG2A 61.1 434 5990*2160*2543 12192*2438*2896
TP2500 2500 2000 2250 1800 4016-61TRG3 61.1 470 6010*2250*2783.5
Download
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Details
Frequently Asked Questions
Q
What is the difference between ESP and PRP ratings in the genset specification table?
ESP (Emergency Standby Power) refers to the maximum power output a generator can deliver for a limited number of hours per year under variable load conditions, typically used as a backup during utility outages. PRP (Prime Rated Power) is the power a generator can supply continuously for an unlimited number of hours per year at variable load, making it suitable for primary power applications. For most standby installations, ESP ratings apply, while PRP ratings are used where the generator serves as the main power source.
Q
What power range does the TP Series generator lineup cover?
The TP Series covers a wide power range from 10 KVA (TP10) up to 2,500 KVA (TP2500) in ESP rating, making it suitable for a broad spectrum of applications — from small commercial facilities and residential backup to large industrial plants, data centers, and infrastructure projects.
Q
What is the difference between Open Type and Canopy Type generators?
Open Type generators have no enclosure, making them more compact and cost-effective, but they require installation in a sheltered machine room or dedicated generator room to protect the unit from weather and reduce noise exposure. Canopy Type generators come with a weather-protective acoustic enclosure, making them suitable for outdoor installation. The canopy significantly reduces operating noise levels and protects the unit from rain, dust, and UV exposure.
Q
How do I select the right TP Series generator model for my project?
To select the correct model, first calculate your total connected load in KW or KVA, then add a safety margin of 20–25% to account for motor starting surges and future load growth. Determine whether you need standby (ESP) or prime (PRP) power. Then match your required KVA output to the appropriate model in the table. Consider also the physical dimensions (Open or Canopy type) to ensure the unit fits your installation site. Downloading the individual model datasheet via the Details button will provide full technical specifications.
Q
What engine brands are used in the TP Series generators?
The TP Series generators are powered by Perkins engines across the entire range. Engine models include the compact 403 and 404 series for smaller outputs (10–22 KVA), the 1103 and 1104 series for mid-range units (33–110 KVA), the 1106 and 1206 series for 150–275 KVA outputs, and the larger 1706, 1506, 2206, 2506, 2806, 4006, 4008, 4012, and 4016 series for high-power applications up to 2,500 KVA. Perkins engines are renowned globally for reliability, fuel efficiency, and ease of servicing.
Q
Where can I download the detailed technical datasheet for each TP Series model?
Each TP Series model has an individual PDF datasheet available for download directly from the specification table above. Click the Details button in the Download column corresponding to your desired model. The PDF contains full technical specifications including electrical data, engine performance curves, dimensional drawings, and installation requirements.