Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

30 kVA – 2000 kVA Range Open & Canopy Types Available Standby & Prime Power Ratings
Genset Model Standby Power Prime Power Engine Model Displacement (L) Fuel Consumption (L/h) Open Type
L*W*H (mm)
Canopy Type
L*W*H (mm)
KVA KW KVA KW
TC30 30 24 27 22 4B3.9-G2 3.9 6.7 1856*835*1351 2396*1056*1723
TC44 44 35 40 32 4BT3.9-G2 3.9 9.3 1856*835*1351 2396*1056*1723
TC62 62 50 56 45 *4BTA3.9-G2 3.9 12.9 1856*835*1351 2396*1056*1723
TC70 70 56 65 52 △4BTA3.9-G2 3.9 14.9 1856*835*1351 2396*1056*1723
TC90 90 72 80 64 4BTA3.9-G11 3.9 17.6 1890*860*1400 3146*1056*1850
TC100 103 82 94 75 *6BT5.9-G2 5.9 22.3 2239*900*1412 3146*1056*1850
TC115 115 92 105 84 △6BT5.9-G2 5.9 24.2 2239*900*1412 3146*1056*1850
TC125 125 100 115 92 6BTA5.9-G2 5.9 27 2239*900*1412 3146*1056*1850
TC145 145 116 135 108 6BTAA5.9-G2 5.9 30 2372*988*1533 3436*1106*1968
TC165 165 132 150 120 6BTAA5.9-G12 5.9 34 * 2400*995*1533 3436*1106*1968
TC200 200 160 180 145 6CTA8.3-G2 8.3 42 2372*988*1533 3436*1106*1968
TC220 215 172 200 160 6CTAA8.3-G2 8.3 45 2584*1008*1667 3686*1256*2068
TC265 264 211 250 200 6LTAA8.9-G2 8.9 53 2584*1008*1667 3686*1256*2068
TC275 275 220 250 200 6LTAA8.9-G3 8.9 54 2584*1008*1667 3686*1256*2068
TC300 300 240 270 216 6LTAA9.5-G3 9.5 58 * 2950*1200*1760 4366*1406*2260
TC315 313 250 275 220 NTA855-G1A 14 61.3 3134*1147*1897 4366*1406*2260
TC350 340 272 310 248 NTA855-G1B 14 71.4 * 3134*1147*1897 4366*1406*2260
TC375 375 300 344 275 NTA855-G2A 14 71.9 3134*1147*1897 4366*1406*2260
TC385 388 310 350 280 NTA855-G4 14 75.3 * 3362*1150*1936 4786*1356*2537
TC410 413 330 375 300 NTAA855-G7 14 85.4 * 3362*1150*1936 4786*1356*2537
TC450 450 360 / / NTAA855-G7A 14 98 3362*1150*1936 4786*1356*2537
TC500 500 400 450 360 KTA19-G3 19 98.8 3452*1360*2131 5306*1566*2585
TC550 563 450 500 400 KTA19-G3A 19 109.6 3452*1360*2131 5306*1566*2585
TC550 563 450 500 400 KTA19-G4 19 109.6 * 3452*1360*2131 5306*1566*2585
TC625 631 505 525 420 KTAA19-G5 19 115.7 3630*1460*2050 6058*2438*2591
TC690 688 550 / / KTAA19-G6A 19 159 3647*1460*2050 6058*2438*2591
TC800 800 640 725 580 KT38-GA 38 174 * 4268*1770*2250 6058*2438*2591
TC825 825 660 750 600 KTA38-G2 38 168.7 4268*1770*2250 6058*2438*2591
TC880 888 710 800 640 KTA38-G2B 38 171.1 4320*2000*2263 6058*2438*2591
TC1000 1000 800 910 728 KTA38-G2A 38 198.8 4320*2000*2263 6058*2438*2591
TC1100 1100 880 1000 800 KTA38-G5 38 214.5 4320*2000*2263 6058*2438*2591
TC1250 1230 984 / / KTA38-G9 38 254 4350*2069*2263 12192*2438*2896
TC1375 1345 1076 1250 1000 KTA50-G3 50 267.5 4980*2060*2399 12192*2438*2896
TC1650 1650 1320 1375 1100 KTA50-G8 50.3 289 5680*2150*2562 12192*2438*2896
TC1650 1650 1320 1475 1180 KTA50-GS8 50 316.9 5680*2150*2562 12192*2438*2896
TC1875 1873 1498 1675 1340 KTA50-G15 50.3 350.6 5555*2050*2420 12192*2438*2896
TC2000 2000 1600 1875 1500 KTA50-G16 50.3 404.8 5990*2160*2543
*4BTA3.9-G2:QC 50/60E    △4BTA3.9-G2:QC 58/67E    *6BT5.9-G2:QC 86/100E    △6BT5.9-G2:QC 96/115E
Frequently Asked Questions
Q What is the difference between Standby Power and Prime Power in these generator sets?
Standby Power (ESP) refers to the maximum output available for use in the event of a utility failure. It is typically used for limited hours per year with varying load. Prime Power (PRP) is the maximum power available for an unlimited number of hours per year with a variable load. For most continuous or critical applications, Prime Power ratings should be used as the reference.
Q What does the asterisk (*) or triangle (△) symbol mean next to some engine models?
These symbols indicate specific engine variants with corresponding alternator configurations. For example: *4BTA3.9-G2 corresponds to QC 50/60E, △4BTA3.9-G2 corresponds to QC 58/67E, *6BT5.9-G2 corresponds to QC 86/100E, and △6BT5.9-G2 corresponds to QC 96/115E. Please refer to the footnote at the bottom of the specification table for the complete reference.
Q What is the difference between Open Type and Canopy Type generator sets?
Open Type generator sets have no enclosure and are generally installed indoors or in a purpose-built generator room. They are more compact and lower in cost. Canopy Type generator sets are enclosed in a weatherproof housing, making them suitable for outdoor installation. The canopy provides protection against rain, dust, and noise reduction. As shown in the table, canopy units are larger in overall dimensions than their open-type counterparts.
Q Which generator set model is suitable for large industrial or data center applications?
For large industrial facilities, hospitals, or data centers requiring high and continuous power output, models such as TC1375 (KTA50-G3, 1345 kVA Standby), TC1650 (KTA50-G8 / KTA50-GS8, 1650 kVA Standby), TC1875 (KTA50-G15, 1873 kVA Standby), and TC2000 (KTA50-G16, 2000 kVA Standby) are ideal. These units feature large-displacement Cummins KTA50 engines and deliver prime power up to 1500 kW.
Q How do I choose the right generator set based on fuel consumption?
Fuel consumption (L/h) is a key factor in calculating operating costs. Smaller models such as the TC30 consume as little as 6.7 L/h, while larger models like the TC2000 consume up to 404.8 L/h at full load. When selecting a generator, consider your average load factor — generators typically operate most efficiently at 70–80% of rated load. Choosing an appropriately sized unit avoids fuel waste from under-loading or overload risk from over-loading.
Q Are custom dimensions or configurations available for these generator sets?
Yes. The dimensions listed in the table represent standard configurations for Open Type and Canopy Type units. Custom configurations — including special enclosures, soundproofing levels, fuel tank capacities, control panel options, and parallel operation setups — can be arranged based on specific project requirements. Please contact our technical team with your site conditions and power needs for a tailored solution.