Leave Your Message
China TY Series Diesel Generator Sets with Yuchai Engines - Reliable Power Solutions from Trusted Suppliers and Factory
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

The unit size and silent (canopy) size listed below are for reference only. Click Details to download the full specification sheet for each model.
Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons (L/h) Open Type L×W×H (mm) Canopy Type L×W×H (mm) Details
KVA KW KVA KW
TY23 22 18 20 16 4D24G6 2.45 4.8 1856×835×1351.5 2396×1056×1723 Details
TY28 28 22 25 20 4D24G7 2.45 6 1856×835×1351.5 2396×1056×1723 Details
TY33 33 26 30 24 4D24TG2 2.45 7.3 1856×835×1351.5 2396×1056×1723 Details
TY41 41 33 38 30 4D24TG0 2.45 9.3 1856×835×1351.5 2396×1056×1723 Details
TY63 63 50 56 45 YC4D80-D34 4.21 14.8 1856×820×1271 2396×1056×1723 Details
TY69 69 55 63 50 YC4D90-D34 4.21 17 1856×835×1351.5 2396×1056×1723 Details
TY80 80 64 75 60 YC4D105-D34 4.21 19.6 2400×995×1428 3146×1056×1850 Details
TY100 100 80 88 70 YC4D120-D31 4.21 21.9 2350×900×1412.5 3146×1056×1850 Details
TY110 110 88 100 80 YC4A140-D30 4.84 25.6 2480×1125×1412.5 3146×1056×1850 Details
TY110 110 88 100 80 YC4D140-D31 4.21 25.6 2150×880×1306 3146×1056×1850 Details
TY125 125 100 113 90 YC4A155-D30 4.84 27.1 2239×900×1412.5 3146×1056×1850 Details
TY125 125 100 113 90 YC4D155-D31 4.21 27.6 2239×900×1412.5 3146×1056×1850 Details
TY125 125 100 113 90 YC4A165-D30 4.84 28.3 2239×900×1412.5 3146×1056×1850 Details
TY150 150 120 138 110 YC4A190-D30 4.84 31.9 2200×950×1436 3436×1106×1968 Details
TY165 163 130 150 120 YC6A205-D30 7.25 35.3 2400×1000×1680 3436×1106×1968 Details
TY188 188 150 175 140 YC6A230-D30 7.25 39.8 2450×1000×1680 3436×1106×1968 Details
TY200 200 160 180 144 YC6A245-D30 7.25 41.8 2450×1000×1680 3436×1106×1968 Details
TY220 220 176 200 160 YC6A275-D30 7.25 47.1 2550×980×1209 3686×1256×2068 Details
TY275 275 220 250 200 YC6MK350-D30 10.34 57.5 2600×1008×1667.5 3686×1256×2068 Details
TY344 340 272 310 248 YC6MK420-D30 10.34 68.3 3150×1147×1897 4366×1406×2260 Details
TY350 375 300 350 280 YC6MK450-D30 10.34 72.6 3174×1147×1897 4366×1406×2260 Details
TY400 400 320 375 300 YC6K500-D30 12.16 83 3200×1360×2050 4786×1356×2537 Details
TY400 400 320 375 300 YC6K500-D31 12.16 83 3200×1360×2050 4786×1356×2537 Details
TY425 425 340 400 320 YC6K520-D30 12.16 87 3250×1360×1995 4786×1356×2537 Details
TY500 500 400 450 360 YC6K600-D30 12.94 101 3350×1360×1818 5306×1566×2585 Details
TY550 550 440 500 400 YC6T660-D31 16.35 113.8 3630×1460×2050 5306×1566×2585 Details
TY625 625 500 563 450 YC6TD780-D31 19.6 137 3650×1460×2000 6058×2438×2591 Details
TY690 688 550 625 500 YC6TD840-D31 19.6 144.5 3680×1670×2029 6058×2438×2591 Details
TY750 738 590 670 536 YC6TD900-D31 19.6 154.3 3680×1460×2150 6058×2438×2591 Details
TY825 825 660 750 600 YC6TD1000-D30 19.6 166.4 4248×1660×2195 6058×2438×2591 Details
TY825 825 660 750 600 YC6C1020-D31 39.58 172.5 4248×1660×2195 6058×2438×2591 Details
TY890 888 710 813 650 YC6C1070-D31 39.58 181.6 4268×1760×2340 6058×2438×2591 Details
TY1000 1000 800 913 730 YC6C1220-D31 39.58 203.7 4380×1771×2463 6058×2438×2591 Details
TY1100 1125 900 1000 800 YC12VTD1350-D30 39.2 225.3 4350×2000×2263 6058×2438×2591 Details
TY1125 1125 900 1000 800 YC6C1320-D31 39.58 220.2 4380×1771×2463 6058×2438×2591 Details
TY1250 1230 984 1125 900 YC6C1520-D31 39.58 253.3 4817×2145×2448 12192×2438×2896 Details
TY1250 1230 984 1125 900 YC12VTD1500-D30 39.2 250.4 4810×2200×2630 12192×2438×2896 Details
TY1375 1345 1076 1250 1000 YC6C1660-D30 39.58 276.8 4668×2033×2198 12192×2438×2896 Details
TY1375 1345 1076 1250 1000 YC12VTD1680-D30 39.2 280.4 4985×2060×2399 12192×2438×2896 Details
TY1375 1345 1076 1250 1000 YC12VC1680-D31 79.17 281.7 4985×2060×2399 12192×2438×2896 Details
TY1500 1500 1200 1375 1100 YC12VTD1830-D30 39.2 305.7 4602×2130×2535 12192×2438×2896 Details
TY1625 1625 1300 1500 1200 YC12VTD2000-D30 39.2 336.8 4516×2200×2611 12192×2438×2896 Details
TY1650 1660 1328 1500 1200 YC12VC2070-D31 79.17 339.2 5620×2555×2836 / Details
TY1875 1873 1498 1688 1350 YC12VC2270-D31 79.17 370.6 5600×2050×2420 / Details
TY2000 2000 1600 1875 1500 YC12VC2510-D31 79.17 416.5 5800×2250×2600 / Details
TY2250 2250 1800 2080 1664 YC12VC2700-D31 79.17 441.9 5820×2250×2600 / Details
TY2500 2500 2000 2250 1800 YC16VC3000-D31 105.56 493.9 6000×2590×2770 / Details
TY2750 2750 2200 2500 2000 YC16VC3300-D31 105.56 543.2 6540×2575×3035 / Details
The above unit size and silent size are for reference only.
Frequently Asked Questions
Q What is the difference between ESP and PRP power ratings on these gensets?
ESP (Emergency Standby Power) is the maximum power available for use in the event of a utility failure. It is intended for variable load applications with no overload capability. PRP (Prime Rated Power) is the power available for unlimited hours of operation at variable load, with a typical average load factor of 70% of PRP over each 24-hour period. PRP ratings are generally lower than ESP ratings for the same engine model.
Q What engine brands are used in the TY Series diesel generator sets?
The TY Series generator sets use Yuchai (YC) engines across the full power range. Smaller models (TY23–TY41) are fitted with 4D24 series engines, mid-range models use YC4D, YC4A, YC6A, YC6MK, and YC6K series engines, while high-power models (TY825–TY2750) are equipped with YC6C, YC12VTD, YC12VC, and YC16VC series engines with displacements up to 105.56 L.
Q What is the difference between Open Type and Canopy Type generator sets?
Open Type generator sets have no enclosure around the engine and alternator, making them suitable for indoor installation or where noise is less of a concern. Canopy Type (also called Silent Type) generator sets are enclosed in a sound-attenuating steel canopy, significantly reducing noise levels and providing weather protection, making them ideal for outdoor use or noise-sensitive environments.
Q How do I choose the right genset model for my power requirements?
First, calculate the total connected load (in KW or KVA) of all equipment you need to power, including startup surge loads for motors and compressors. For standby applications, select a model whose ESP KW rating exceeds your total load. For continuous or prime power use, select based on PRP KW. It is generally recommended to size the generator at 70–80% of its rated capacity for optimal performance and longevity. Please download the individual datasheet for detailed electrical specifications.
Q Are detailed technical specifications and dimension drawings available for each model?
Yes. Each model in the table above has a downloadable PDF datasheet accessible via the Details button. The datasheet includes full electrical specifications, engine parameters, dimensional drawings for both open and canopy configurations, and weight information. Please note that the dimensions listed in the table are for reference only; always refer to the official datasheet for engineering and installation planning.
Q Can the same genset model be configured with different engine options?
Yes. Several models in the TY Series are available with multiple engine options to suit different application requirements, emission standards, or regional preferences. For example, the TY110, TY125, TY400, TY825, and TY1375 models each offer two or more engine variants with slightly different displacements, fuel consumption figures, and physical dimensions. Each variant has its own dedicated datasheet available for download.
layer-517