Leave Your Message
Diesel Generator Sets with Baudouin Engines - China Suppliers & Factory, 20kVA to 2750kVA Power Range
Hot Products

Diesel Generator Sets with Cummins Engines, TC Series

TC series diesel generator sets are powered by Cummins engines.
Power range 30kVA-2000kVA
- Adopting Cummins engines, offering cutting-edge design, dependable performance and long service life;
- Continuous operation with high combustion efficiency and low fuel consumption;

Meet the TC Series

TC1100T

Specifications

Scroll right to view full table
Genset Model ESP PRP Engine Model Displacement (L) Fuel Cons L/h Open Type L*W*H (mm) Canopy Type L*W*H (mm) Download
KVA KW KVA KW
TB20 20 16 18 15 4M06G20/5 2.3 4.7 1425*680*1140 2396*1056*1723 Details
TB25 25 20 23 18 4M06G25/5 2.3 6.1 1460*680*1140 2396*1056*1723 Details
TB35 35 28 32 26 4M06G35/5 2.3 7.6 1580*735*1150 2396*1056*1723 Details
TB44 44 35 40 32 4M06G44/5 2.3 9.5 1600*735*1150 2396*1056*1723 Details
TB50 50 40 45 36 4M06G50/5 2.3 10.7 1565*680*1150 2396*1056*1723 Details
TB55 55 44 50 40 4M06G55/5 2.3 11.9 1585*680*1150 2396*1056*1723 Details
TB72 72 57 65 52 4M10G70/5 4.087 15 1890*785*1240 3146*1056*1850 Details
TB88 88 70 80 64 4M10G88/5 4.087 18.8 1940*785*1240 3146*1056*1850 Details
TB110 110 88 100 80 4M10G110/5 4.087 21.3 1965*791*1345 3146*1056*1850 Details
TB150 150 120 135 108 6M11G150/5 6.75 30.2 2400*860*1460 3436*1106*1968 Details
TB165 165 132 150 120 6M11G165/5 6.75 32.6 2400*860*1460 3436*1106*1968 Details
TB220 220 176 200 160 6M16G220/5 9.726 43.1 2715*1085*1615 3686*1256*2068 Details
TB250 250 200 230 184 6M16G250/5 9.726 50.9 2770*1085*1615 3686*1256*2068 Details
TB275 275 220 250 200 6M16G275/5 9.726 56.9 2770*1085*1615 3686*1256*2068 Details
TB350 350 280 320 256 6M16G350/5 9.726 70.5 2895*1135*1660 4366*1406*2260 Details
TB400 400 320 375 300 6M21G400/5 12.54 82.1 3010*1150*1715 4786*1356*2537 Details
TB440 440 352 400 320 6M21G440/5 12.54 85.5 3010*1150*1715 4786*1356*2537 Details
TB500 500 400 450 360 6M21G500/5 12.54 96.58 3055*1155*1725 5306*1566*2585 Details
TB550 550 440 500 400 6M21G550/5 12.54 109.5 3140*1285*1840 5306*1566*2585 Details
TB660 660 528 600 480 6M33G660/5 19.6 126.5 3555*1360*2085 6058*2438*2591 Details
TB715 715 572 650 520 6M33G715/5 19.6 136.3 3630*1360*2085 6058*2438*2591 Details
TB750 738 590 670 536 6M33G750/5 19.6 151.1 3630*1360*2085 6058*2438*2591 Details
TB825 825 660 750 600 6M33G825/5 19.6 161.5 3700*1360*2085 6058*2438*2591 Details
TB900 900 720 815 652 12M26G900/5 31.8 173.7 4210*1800*2500 Please contact us if necessary Details
TB1000 1000 800 900 720 12M26G1000/5 31.8 195.5 4210*1800*2500 Details
TB1120 1120 898 1020 816 12M26G1100/5 31.8 207.1 4330*1800*2500 Details
TB1250 1230 984 1150 920 12M33G1250/5 39.2 236.2 4625*1925*2745 Details
TB1400 1400 1120 1250 1000 12M33G1400/5 39.2 258.6 4720*1925*2745 Details
TB1500 1500 1200 1375 1100 12M33G1500/5 39.2 296.9 4720*1925*2745 Details
TB1650 1650 1320 1500 1200 12M33G1650/5 39.2 324 4755*2295*2740 Details
TB1900 1873 1498 1750 1400 16M33G1900/5 52.3 364.3 5170*2290*2835 Details
TB2000 2000 1600 1875 1500 16M33G2000/5 52.3 401 5170*2290*2835 Details
TB2250 2250 1800 2000 1600 16M33G2250/5 52.3 485.3 5375*2810*3220 Details
TB2500 2500 2000 2250 1800 20M33G2500/5 65.4 495 6685*2295*3005 Details
TB2750 2750 2200 2500 2000 12M55G2750/5 65.65 513.9 6530*2300*3140 Details
ⓘ The above unit size and silent size are for reference only.
Frequently Asked Questions
What is the difference between ESP and PRP power ratings in the genset specification table?
ESP (Emergency Standby Power) is the maximum power available for use in the event of a utility failure, typically rated for up to 200 hours per year with a variable load. PRP (Prime Rated Power) is the power available for continuous operation with a variable load for an unlimited number of hours per year. PRP is generally around 10% lower than ESP for the same generator model.
What is the difference between an Open Type and a Canopy Type genset?
An Open Type genset has no enclosure, making it more compact and lower in cost, but it is not weather-proof and is typically installed indoors or in a dedicated generator room. A Canopy Type (also called a Silent or Soundproof type) genset is enclosed in a weather-resistant acoustic canopy, reducing noise levels significantly and allowing outdoor installation. The canopy dimensions listed in the table are larger than the open type accordingly.
How do I choose the right genset model for my application?
To select the right genset, first calculate your total load requirements in KW or KVA. If the generator is for emergency backup use, choose a model whose ESP rating meets or exceeds your load. If it will run continuously as a prime power source, use the PRP rating as your reference. Consider also the installation environment — choose a Canopy Type for outdoor or noise-sensitive locations. For large-scale requirements above 900 KVA, please contact us directly for customized solutions.
What engine brands are used in the TB series gensets?
The TB series gensets use engines from the 4M, 6M, 12M, 16M, and 20M engine families as indicated in the Engine Model column of the specification table. These engines span displacements from 2.3L (smaller models such as TB20–TB55) up to 65.65L (TB2750), ensuring reliable performance across the full power range from 20 KVA to 2750 KVA.
Are the dimensions listed in the table exact for all configurations?
The L*W*H dimensions provided for both Open Type and Canopy Type gensets are for reference only, as stated at the bottom of the specification table. Actual dimensions may vary slightly depending on optional accessories, configuration, and manufacturing tolerances. Please download the detailed PDF datasheet for each model or contact us for precise engineering drawings before installation planning.
How can I obtain detailed technical specifications or a quotation for a specific model?
Each model in the table has a "Details" download button that links directly to a PDF datasheet containing full technical specifications. For models above TB825 requiring a Canopy Type enclosure, or for any custom configuration, please contact our sales team directly. We are happy to provide tailored quotations, engineering support, and after-sales service for all TB series genset models.
layer-517
contacts+

SEND INQUIRY

Receive updates and discounts from companies+contact us

CONTACT US